首页> 外文期刊>Filtration news >Municipal Filter Press Sludge Dewatering Testing
【24h】

Municipal Filter Press Sludge Dewatering Testing

机译:市政压滤机污泥脱水测试

获取原文
获取原文并翻译 | 示例
           

摘要

Municipal sewage sludge de-watering problems are well known with standard recess filter presses. (Photo 1) These problems are mainly associated with long dewatering cycles, press cloth blinding and short life, and the lack of suitable lab tests for predicting performance. As a result, a series of on-site 470mm pilot tests were conducted. These tests demonstrated that cloth blinding wasn't an issue but that underdrain condition was important (i.e., both the underdrain cloths as well as the plate drainage grooves) (1). In addition, it was concluded that membrane plates offer no advantage over the current standard recess operation; and that the "long dewatering tail" phenomenon could not be duplicated in the 470mm pilot press.
机译:使用标准凹式压滤机众所周知的市政污水污泥脱水问题。 (照片1)这些问题主要与较长的脱水周期,压榨布致盲,使用寿命短以及缺乏合适的实验室测试来预测性能有关。结果,进行了一系列的现场470mm中试。这些测试表明,布的盲目性不是问题,但排水条件很重要(即排水布和板排水槽都如此)(1)。此外,得出的结论是,与目前的标准凹口操作相比,隔膜板没有优势。并且“长脱水尾巴”现象在470mm中压机中无法复制。