首页> 外文期刊>Experimental Heat Transfer >EFFECTS OF THE PITCH OF IN-LINE DELTA WINGLET VORTEX GENERATORS ON HEAT TRANSFER OF A FINNED THREE-ROW FLAT TUBE BANK
【24h】

EFFECTS OF THE PITCH OF IN-LINE DELTA WINGLET VORTEX GENERATORS ON HEAT TRANSFER OF A FINNED THREE-ROW FLAT TUBE BANK

机译:串联三角形小翼涡发生器的节距对三排扁平管式换热器传热的影响

获取原文
获取原文并翻译 | 示例
       

摘要

The naphthalene sublimation technique via the heat and mass transfer analogy is used to study the effects of the pitch of in-line delta winglet vortex generators on heat transfer and pressure drop of a finned three-row flat tube bank. The results show that the pitch of the in-line vortex generator has a strong effect on the heat transfer performance. The optimal pitch depends on the performance evaluation criteria. With the configurations considered in this article, for identical pumping power or combined constraint, a small pitch of 0.33 is best; for the identical pressure drop constraint, a value of 0.42 is best.
机译:通过传热和传质类似物的萘升华技术被用于研究直列三角翼小涡流发生器的螺距对翅片式三排扁管束的传热和压降的影响。结果表明,在线涡流发生器的螺距对传热性能有很大影响。最佳音高取决于性能评估标准。使用本文中考虑的配置时,对于相同的泵浦功率或组合约束,最好使间距为0.33,这是最好的。对于相同的压降约束,最佳值为0.42。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号