首页> 外文期刊>European Spine Journal >Estimation of the centre of mass for the study of postural control in Idiopathic Scoliosis patients: a comparison of two techniques
【24h】

Estimation of the centre of mass for the study of postural control in Idiopathic Scoliosis patients: a comparison of two techniques

机译:特发性脊柱侧弯患者姿势控制研究的重心估计:两种技术的比较

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of the present study is to quantify the position of the Centre of Mass (COM) during quiet standing using a force plate and compare this technique to the quantification of the COM with an anthropometric model. The postural control of 18 healthy adolescents and 22 IS patients was evaluated using an Optotrak 3D kinematic system, and two AMTI force plates during quiet standing. The position of anatomical landmarks tracked by the Optotrak system served to estimate the position of the COM of both groups using an anthropometric model (COManth). The force plate served to estimate the position of the COM through double integration of the horizontal ground reaction forces (COMgl). The mean position and root mean square (RMS) amplitude of COMgl, in reference to the base of support (BOS) and the first sacral prominence (S1) were quantified in the Anterior–Posterior (A/P) and Medial–Lateral (M/L) directions. There was a significant difference between the control subjects and IS patients for the displacement of the COMgl in reference to the BOS in both the A/P and M/L directions. There was no difference between groups for the mean position of the COMgl, however, 63% of the IS and 43% of the controls had a lateral position of the COMgl in reference to S1 of greater than 5 mm. There was a significant difference between groups in the A/P and M/L directions for the amplitude of error between the COMgl and COManth techniques.
机译:本研究的目的是使用力板对安静站立时质心(COM)的位置进行量化,并将该技术与人体测量模型对COM的量化进行比较。在安静站立期间,使用Optotrak 3D运动系统和两个AMTI推力板评估了18名健康青少年和22名IS患者的姿势控制。 Optotrak系统跟踪的解剖标志的位置用于使用人体测量模型(COManth )估算两组COM的位置。测力板通过水平地面反作用力(COMgl )的双重积分来估计COM的位置。 相对于支撑基础(BOS)和第一骨隆起(S1)的COMgl的平均位置和均方根(RMS)幅度在前-后(A / P)和内侧–横向(M / L)方向。对照对象和IS患者之间COMgl 相对于BOS在A / P和M / L方向上的位移存在显着差异。两组之间的COMgl 的平均位置没有差异,但是,相对于S1,63%的IS和43%的对照组的COMgl 的侧面位置大于5毫米COMgl 和COManth 技术之间的误差幅度在A / P和M / L方向上各组之间存在显着差异。

著录项

  • 来源
    《European Spine Journal》 |2008年第3期|355-360|共6页
  • 作者单位

    Faculté de médecine Succursale Centre-ville Montréal Université de Montréal C.P. 6128 Montreal QC Canada H3C 3J7;

    Centre de Recherche Centre de Réadaptation Marie Enfant Hôpital Sainte-Justine 5200 Bélanger Est H1T 1C9 Montreal QC Canada;

    Faculté de médecine Succursale Centre-ville Montréal Université de Montréal C.P. 6128 Montreal QC Canada H3C 3J7;

    Faculté de médecine Succursale Centre-ville Montréal Université de Montréal C.P. 6128 Montreal QC Canada H3C 3J7;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Biomechanics; Posture; Idiopathic Scoliosis; Adolescent; Anthropometry; Force plate;

    机译:生物力学;姿势;特发性脊柱侧弯;青少年;人体测量;力板;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号