首页> 外文期刊>European Radiology >Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader
【24h】

Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader

机译:比较使用MDCT作为同时读取器或第二读取器时肺结节的计算机辅助检测(CAD)的灵敏度和读取时间

获取原文
获取原文并翻译 | 示例
       

摘要

The purpose of this study was to compare sensitivity for detection of pulmonary nodules in MDCT scans and reading time of radiologists when using CAD as the second reader (SR) respectively concurrent reader (CR). Four radiologists analyzed 50 chest MDCT scans chosen from clinical routine two times and marked all detected pulmonary nodules: first with CAD as CR (display of CAD results immediately in the reading session) and later (median 14 weeks) with CAD as SR (display of CAD markers after completion of first reading without CAD). A Siemens LungCAD prototype was used. Sensitivities for detection of nodules and reading times were recorded. Sensitivity of reading with CAD as SR was significantly higher than reading without CAD (p < 0.001) and CAD as CR (p < 0.001). For nodule size of 1.75 mm or above no significant sensitivity difference between CAD as CR and reading without CAD was observed; e.g., for nodules above 4 mm sensitivity was 68% without CAD, 68% with CAD as CR (p = 0.45) and 75% with CAD as SR (p < 0.001). Reading time was significantly shorter for CR (274 s) compared to reading without CAD (294 s; p = 0.04) and SR (337 s; p < 0.001). In our study CAD could either speed up reading of chest CT cases for pulmonary nodules without relevant loss of sensitivity when used as CR, or it increased sensitivity at the cost of longer reading times when used as SR.
机译:这项研究的目的是比较当使用CAD作为第二阅读器(SR)和同时阅读器(CR)时,在MDCT扫描中检测肺结节的敏感性和放射线医师的阅读时间。四位放射科医生两次分析了从临床常规中选择的50次胸部MDCT扫描,并标记了所有检测到的肺结节:首先将CAD作为CR(在阅读过程中立即显示CAD结果),随后(中位14周)以CAD作为SR(显示第一次读取完成后不使用CAD的CAD标记)。使用了西门子LungCAD原型。记录检测结节和读取时间的敏感性。以CAD作为SR的阅读敏感性显着高于无CAD的阅读(p <0.001)和CAD作为CR的阅读(p <0.001)。对于1.75 mm或更大的结节大小,没有观察到CAD作为CR和没有CAD的读数之间的显着灵敏度差异;例如,对于4 mm以上的结节,不使用CAD的敏感性为68%,使用CAD作为CR的敏感性为68%(p = 0.45),使用CAD作为SR的敏感性为75%(p <0.001)。与没有CAD的阅读(294 s; p = 0.04)和SR(337 s; p <0.001)相比,CR(274 s)的阅读时间明显缩短。在我们的研究中,CAD可用作CR时可加快胸部CT病例的肺结节读取速度,而不会导致敏感性的相关损失,或者,用作SR时,它会以更长的读取时间为代价来提高灵敏度。

著录项

  • 来源
    《European Radiology》 |2007年第11期|2941-2947|共7页
  • 作者单位

    Department of Clinical Radiology University Hospital Muenster Albert-Schweitzer-Str. 33 48129 Muenster Germany;

    Department of Clinical Radiology University Hospital Muenster Albert-Schweitzer-Str. 33 48129 Muenster Germany;

    Department of Clinical Radiology University Hospital Muenster Albert-Schweitzer-Str. 33 48129 Muenster Germany;

    Department of Clinical Radiology University Hospital Muenster Albert-Schweitzer-Str. 33 48129 Muenster Germany;

    CAD Group Siemens Medical Solutions USA Inc. 51 Valley Stream Parkway Malvern PA 19355 USA;

    Department of Clinical Radiology University Hospital Muenster Albert-Schweitzer-Str. 33 48129 Muenster Germany;

    Department of Clinical Radiology University Hospital Muenster Albert-Schweitzer-Str. 33 48129 Muenster Germany;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Computed tomography (CT); Lung; Nodule; Computer; Diagnostic aid;

    机译:计算机断层扫描(CT);肺;结节;计算机;诊断辅助;