Field-based atrazine sampling rates (R-s) obtained by the polar organic chemical integrative sampler (POCIS) method were measured in 9 headwater streams over 3 yr covering 5 to 6 exposure periods of 2 to 3 wk/site/yr. Rates were best in line with the model R-s = 148 mL/d, with a standard deviation of 0.17 log units (factor 1.5). The POCIS canisters reduced mass transfer coefficients of the water boundary layer by a factor of 2 as measured by alabaster dissolution rates. A mechanistic model that accounts for flow and temperature effects yielded a fair estimate of the effective exchange surface area (12.5 +/- 0.8 cm(2)). This model could only be tested for higher flow velocities because of uncertainties associated with the measurement of flow velocities Environ Toxicol Chem 2020;00:1-9. (c) 2020 SETAC
机译:通过极性有机化学整合取样器(POCIS)(POCIS)方法获得的基于现场的阿特拉津采样率(R-S)在9个下覆盖5至6个暴露时段为2至3WK /位点/ Yr的9个下水流中测量。利率与型号R-S = 148毫升/天最佳,标准偏差为0.17日志单位(因子1.5)。 Pocis罐通过氧化铝体溶解率测量的倍数2的水边界层的质量转移系数。对流动和温度效应进行考虑的机械模型产生了有效交换表面积的公平估计(12.5 +/- 0.8cm(2))。由于与流速氛围的不确定性,该模型仅对更高的流速进行了测试,因为与流速环境毒素Chem 2020; 00:1-9的测量。 (c)2020 Setac