首页> 外文期刊>Environmental toxicology and chemistry >SMALL BUT DIFFERENT EFFECT OF FOULING ON THE UPTAKE RATES OF SEMIPERMEABLE MEMBRANE DEVICES AND POLAR ORGANIC CHEMICAL INTEGRATIVE SAMPLERS
【24h】

SMALL BUT DIFFERENT EFFECT OF FOULING ON THE UPTAKE RATES OF SEMIPERMEABLE MEMBRANE DEVICES AND POLAR ORGANIC CHEMICAL INTEGRATIVE SAMPLERS

机译:腐烂对半透膜设备和极性有机化学集成样品吸收速率的不同影响

获取原文
获取原文并翻译 | 示例
           

摘要

Semipermeable membrane devices (SPMD) and polar organic chemical integrative samplers (POCIS) were exposed to a cocktail of organic chemicals using a flow-through system. Samplers were removed and analyzed every 7 d over a four-week period in order to determine sampling rates (R_s) for individual compounds. Prior to laboratory exposure, half of the samplers were allowed to foul naturally for six weeks, in order to examine differences in uptake due to fouling. The amount of fouling ranged from 0.2 to 2.8 g dry weight/dm~2 for POCIS and 0.1 to 1.4 g dry weight/dm~2 for SPMDs, and the pattern of accumulation was also different between them. The R_s values were determined by fitting curves to time course uptake data and also by using performance reference compounds (PRCs) for SPMDs. Sampling rates ranged from 2.7 to 14.2 L/d for SPMDs and 0.01 to 0.27 L/d for POCIS. Fouled SPMDs showed a reduction in R_s (<20%) for all but one compound, and there was a similar reduction in the release of PRCs. However, PRC-predicted R_s values were overall somewhat higher than those from fitted curves. Uptake of alkylated phenols in POCIS was generally higher (up to 55%) in fouled samplers. The reason for this is not known, but is possibly due to some reduction in interactions with the membrane in fouled samplers. There was no overall pattern in the relationship of sampling rate differences with log A_(ow) or over time for either sampler. Release of compounds from POCIS after a drop in exposure water concentrations provides some encouragement for the application of a PRC approach to polar passive samplers.
机译:使用流通系统将半透膜设备(SPMD)和极性有机化学综合采样器(POCIS)暴露于有机化学混合物中。移出采样器并在四周的时间内每7天分析一次,以确定各个化合物的采样率(R_s)。在实验室暴露之前,让一半的采样器自然污损六周,以检查由于污垢引起的摄取差异。 POCIS的结垢量为0.2至2.8 g干重/ dm〜2,而SPMD的结垢量为0.1至1.4 g干重/ dm〜2,它们之间的积聚模式也不同。 R_s值是通过将曲线拟合到时程吸收数据并使用SPMD的性能参考化合物(PRC)来确定的。 SPMD的采样率范围为2.7至14.2 L / d,而POCIS的采样率范围为0.01至0.27 L / d。除一种化合物外,结垢的SPMD均显示R_s降低(<20%),并且PRCs的释放也有类似的降低。但是,PRC预测的R_s值总体上高于拟合曲线的值。在结垢的采样器中,POCIS中烷基化苯酚的摄入量通常更高(高达55%)。其原因尚不清楚,但可能是由于污垢采样器中与膜的相互作用有所减少。对于任何一个采样器,采样率差异与log A_(ow)或随时间的关系都没有总体模式。暴露水浓度降低后,化合物从POCIS中释放出来,为将PRC方法应用于极性无源采样器提供了一些鼓励。

著录项

  • 来源
    《Environmental toxicology and chemistry》 |2009年第11期|2324-2332|共9页
  • 作者单位

    Norwegian Institute for Water Research, Oslo Centre for Interdisciplinary Environmental and Social Research, Gaustadalleen 21, NO-0349 Oslo, Norway Department of Chemistry, University of Oslo, P.O. Box 1033, Blindern, Oslo, Norway;

    Norwegian Institute for Water Research, Oslo Centre for Interdisciplinary Environmental and Social Research, Gaustadalleen 21, NO-0349 Oslo, Norway;

    Norwegian Institute for Water Research, Oslo Centre for Interdisciplinary Environmental and Social Research, Gaustadalleen 21, NO-0349 Oslo, Norway;

    Norwegian Institute for Water Research, Oslo Centre for Interdisciplinary Environmental and Social Research, Gaustadalleen 21, NO-0349 Oslo, Norway;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    passive sampling; biofouling; exposure studies; polycyclic aromatic hydrocarbons; alkylphenols;

    机译:被动采样;生物污染接触研究;多环芳烃;烷基酚;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号