Gas and bed temperatures were studied in a 4.4 m by 12 m, co-current flow, slagging rotary kiln at a commercial hazardous waste incinerator. The visual observations used by the kiln operators to control the process are described. These observations were quantified using thermocouples, radiation pyrometers, and phase-change indicators. The objectives were to estimate the peak bed temperature and compare this to measurements at the kiln exit. The maximum bed temperature occurs toward the middle of this type of kiln and not at the discharge. The slag melting temperature and test pellets with known melting points indicate that the peak bed temperature can be 100-300 K higher than the kiln exit temperature reported by the permanent instruments at this facility. Both broad-band radiation pyrometers and thermocouples give a qualitative temperature indication that can be used for process control, but the readings depend on the sensor locations relative to the incompletely mixed air and combustion products. Two-color radiation pyrometer measurements of surface temperature near the kiln exit are higher than the actual temperature due to reflected radiation.
机译:在商用危险废物焚烧炉中,在4.4 m x 12 m并流的带渣回转窑中研究了气体和床层温度。描述了窑经营者用来控制过程的视觉观察。使用热电偶,辐射高温计和相变指示器对这些观察结果进行了量化。目的是估计最高床温并将其与窑出口处的测量值进行比较。最高床温发生在这种窑的中间,而不是在出料口。炉渣的熔化温度和已知熔点的试验球团表明,峰值床温可以比该工厂永久性设备报告的窑出口温度高100-300K。宽带辐射高温计和热电偶都给出了可用于过程控制的定性温度指示,但读数取决于传感器相对于未完全混合的空气和燃烧产物的位置。由于反射辐射,窑出口附近表面温度的双色辐射高温计测量值高于实际温度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号