首页> 外文期刊>Environmental Science & Technology >Effects of Sampling Artifacts and Operating Parameters on the Performance of a Semicontinuous Particulate Elemental Carbon/ Organic Carbon Monitor
【24h】

Effects of Sampling Artifacts and Operating Parameters on the Performance of a Semicontinuous Particulate Elemental Carbon/ Organic Carbon Monitor

机译:采样工件和操作参数对半连续颗粒物碳/有机碳监测仪性能的影响

获取原文
获取原文并翻译 | 示例
       

摘要

The carbonaceous component of atmospheric paniculate matter (PM) is considered very important with respect to the observed adverse health effects of PM.Particulate organic and elemental carbon have traditionally been measured off-line after daily,time-integrated particle collection on filters.However,the subdaily or hourly variability of elemental carbon (EC) and organic carbon (OC) can help to assess the variability of sources,ambient levels,and human exposure.In this study,the performance of the Sunset Laboratory Inc.Semicontinuous EC/OC monitor was assessed in a Los Angeles location representing typical urban pollution.An intermonitor comparison showed high precision (R~2 of 0.98 and 0.97 for thermal OC and EC,respectively).By changing the inlet configurations of one of the monitors (adding a denuder,a Teflon filter,or both),the influences of positive and negative sampling artifacts were investigated.The positive artifact was found to be relatively large (7.59 mug/m~3 on average),more than 50% of measured OC,but it was practically eliminated with a denuder.The negative artifact was much smaller (less than 20% of the positive artifact) and may be neglected in most cases.A comparison of different temperature profiles,including a fast 4-min analysis using optical EC correction,showed good agreement among methods.Finally,a novel configuration using a size selective inlet impactor removing particles greater than 250 nm in diameter allowed for Semicontinuous size-fractionated EC/OC measurements.Evolution of OC at different temperatures of the thermal analysis showed higher volatility OC in larger particles.
机译:就观察到的PM不利健康影响而言,大气颗粒物(PM)的碳质成分非常重要。传统上,每天对颗粒物进行定期收集后,离线测量颗粒有机和元素碳。元素碳(EC)和有机碳(OC)的每日或每小时的可变性可以帮助评估来源,环境水平和人体暴露的可变性。在本研究中,Sunset Laboratory Inc.半连续EC / OC监测器的性能在代表典型城市污染的洛杉矶地区进行了评估。显示器间的比较显示出较高的精度(热OC和EC的R〜2分别为0.98和0.97)。通过更改其中一台显示器的进气口配置(添加消光器,聚四氟乙烯过滤器(或同时使用两者),研究了正负采样伪像的影响。发现正伪像相对较大(平均7.59杯/ m〜3),mo小于测量的OC的50%,但实际上已被剥蚀仪消除了。负伪影很小(小于正伪影的20%),在大多数情况下可以忽略不计。不同温度曲线的比较,包括使用光学EC校正进行的快速4分钟分析显示了方法之间的良好一致性。最后,使用尺寸选择性入口撞击器去除直径大于250 nm的颗粒的新颖配置允许进行半连续尺寸分级的EC / OC测量。不同温度的热分析表明,较大颗粒中的OC挥发度较高。

著录项

  • 来源
    《Environmental Science & Technology》 |2006年第3期|p.945-954|共10页
  • 作者单位

    Department of Civil and Environmental Engineering, University of Southern California,3620 South Vermont Avenue,Los Angeles,California 90089;

    Department of Civil and Environmental Engineering, University of Southern California,3620 South Vermont Avenue,Los Angeles,California 90089;

    Department of Civil and Environmental Engineering, University of Southern California,3620 South Vermont Avenue,Los Angeles,California 90089;

    Department of Civil and Environmental Engineering, University of Southern California,3620 South Vermont Avenue,Los Angeles,California 90089;

    Department of Civil and Environmental Engineering, University of Southern California,3620 South Vermont Avenue,Los Angeles,California 90089;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);