A coin-sized passive emission colorimetric sensor (PECS) based on an enzymatic reaction and a portable reflectance photometry device were developed to determine the emission rates of formaldehyde from building materials and other materials found indoors in only 30 minutes on-site. The color change of the PECS linearly correlated to the concentration of formaldehyde aqueous solutions up to 28 μg/mL The correlation between the emission rates measured by using the PECS and those measured by using a desiccator method or by using a chamber method was fitted with a linear function and a power function, and the determination coefficients were more than 0.98. The reproducible results indicate that the emission rates could be obtained with the correlation equations from the data measured by using the PECS and the portable reflectance photometry device. Limits of detection (LODs) were 0.051 mg/L for the desiccator method and 3.1 μg/m~2/h for the chamber method. Thus, it was confirmed that the emission rates of formaldehyde from the building materials classified as F four-star (< 0.3 mg/L (desiccator method) or < 5.0 μg/m~2/h (chamber method)), based on Japanese Industrial Standards (JIS), could be measured with the PECS. The measurement with PECS was confirmed to be precise (RSD < 10%). Other chemicals emitted from indoor materials, such as methanol, ethanol, acetone, toluene, and xylene, interfered little with the measurement of formaldehyde emission rates by using the PECS.
机译:开发了一种基于酶反应的硬币大小的无源发射比色传感器(PECS)和便携式反射光度法,以测定现场仅30分钟即可从室内发现的建筑材料和其他材料中甲醛的排放率。 PECS的颜色变化与高达28μg/ mL的甲醛水溶液的浓度线性相关。使用PECS测量的排放率与使用干燥器方法或使用室法测量的排放率之间的相关性与线性函数和幂函数,测定系数均大于0.98。可再现的结果表明,可以通过使用PECS和便携式反射光度法测量的数据,利用相关方程从相关方程中获得发射率。干燥器方法的检出限(LODs)为0.051 mg / L,腔室法的检出限为3.1μg/ m〜2 / h。因此,基于日语,证实了被分类为F四星(<0.3 mg / L(干燥剂法)或<5.0μg/ m〜2 / h(室法))的建筑材料中甲醛的排放率。工业标准(JIS)可以使用PECS进行测量。确认使用PECS进行的测量是精确的(RSD <10%)。室内材料排放的其他化学物质,例如甲醇,乙醇,丙酮,甲苯和二甲苯,对使用PECS测出的甲醛排放率几乎没有影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号