首页> 外文期刊>Environmental Science & Technology >PAH-CALUX, an Optimized Bioassay for AhR-Mediated Hazard Identification of Polycyclic Aromatic Hydrocarbons (PAHs) as Individual Compounds and in Complex Mixtures
【24h】

PAH-CALUX, an Optimized Bioassay for AhR-Mediated Hazard Identification of Polycyclic Aromatic Hydrocarbons (PAHs) as Individual Compounds and in Complex Mixtures

机译:PAH-CALUX,一种用于AhR介导的多环芳烃(PAH)作为单个化合物和复杂混合物的危险性鉴定的优化生物测定法

获取原文
获取原文并翻译 | 示例
       

摘要

Polycyclic aromatic hydrocarbons (PAHs) represent a class of ubiquitously occurring environmental compounds that are implicated in a wide range of toxicological effects. Routine measurement of PAH contamination generally involves chemical analytical analysis of a selected group of representatives, for example, EPA-16, which may result in underestimation of the PAH-related toxicity of a sample. Many high molecular weight PAHs are known ligands of the aryl hydrocarbon receptor (AhR), a nuclear receptor that mediates toxic effects related to these compounds. Making use of this property we developed a PAH CALUX assay, a mammalian, H4IIe- cell-based reporter assay for the hazard identification of total PAH mixtures. The PAH CALUX reporter cell line allows for specific, rapid (4 h exposure time) and reliable quantification of AhR-induced luciferase induction relative to benzo[a]pyrene (BaP), which is used as a positive reference PAH congener. Full dose response relationships with inductions over 100-fold were reached within only 2 h of exposure to BaP. The PAH CALUX is highly sensitive, that is, using a 4 h exposure time, a limit of detection (LOD) of 5.2 × 10~(-11) M BaP was achieved, and highly accurate, that is, a repeatability of 5.9% and a reproducibility of 6.6% were established. Screening of a selection of PAHs that were prioritized by the European Union and/or the U.S. Environmental Protection Agency showed that the PAH CALUX bioassay has a high predictability, particularly for carcinogenic PAHs. Experiments with synthetic mixtures and reference materials containing complex PAH mixtures show the suitability of the assay for these types of applications. Moreover, the presented results suggest that application of the PAH CALUX will result in a lower risk of underestimation of the toxicity of a sample than chemical analytical approaches that focus on a limited set of prioritized compounds.
机译:多环芳烃(PAH)代表了一类普遍存在的环境化合物,与多种毒理作用有关。 PAH污染的常规测量通常涉及对一组选定代表的化学分析分析,例如EPA-16,这可能会导致低估样品中与PAH相关的毒性。许多高分子量PAH是芳烃受体(AhR)的配体,芳烃受体是介导与这些化合物相关的毒性作用的核受体。利用这一特性,我们开发了PAH CALUX测定法,这是一种基于哺乳动物,H4IIe细胞的报告基因测定法,用于总PAH混合物的危险性鉴定。 PAH CALUX报告细胞系相对于用作正参考PAH同系物的苯并[a] re(BaP),可以对AhR诱导的萤光素酶诱导进行特异性,快速(4 h暴露时间)和可靠的定量。在暴露于BaP的仅2小时内就达到了与100倍以上诱导相关的全剂量反应关系。 PAH CALUX具有很高的灵敏度,即使用4小时的曝光时间,可以达到5.2×10〜(-11)M BaP的检测限(LOD),并且具有很高的准确性,即5.9%的可重复性重现性为6.6%。对欧盟和/或美国环境保护局优先选择的PAH进行的筛选显示,PAH CALUX生物测定具有很高的可预测性,尤其是对于致癌的PAH。使用合成混合物和包含复杂PAH混合物的参考材料进行的实验表明,该测定方法适用于这些类型的应用。此外,提出的结果表明,与专注于一组有限的优先化合物的化学分析方法相比,PAH CALUX的应用将导致低估样品毒性的风险。

著录项

  • 来源
    《Environmental Science & Technology》 |2013年第20期|11651-11659|共9页
  • 作者单位

    BioDetection Systems BV., Science Park 406. Amsterdam, The Netherlands;

    BioDetection Systems BV., Science Park 406. Amsterdam, The Netherlands;

    BioDetection Systems BV., Science Park 406. Amsterdam, The Netherlands;

    BioDetection Systems BV., Science Park 406. Amsterdam, The Netherlands;

    BioDetection Systems BV., Science Park 406. Amsterdam, The Netherlands;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 14:02:17

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号