首页> 外文期刊>Environmental Science & Technology >Kinetic Passive Sampling: In Situ Calibration Using the Contaminant Mass Measured in Parallel Samplers with Different Thicknesses
【24h】

Kinetic Passive Sampling: In Situ Calibration Using the Contaminant Mass Measured in Parallel Samplers with Different Thicknesses

机译:动力学被动采样:原位校准使用在具有不同厚度的并联采样器中测量的污染物质量

获取原文
获取原文并翻译 | 示例
       

摘要

The use of single-phase passive samplers is a common method for sampling bioavailable concentrations of hydrophobic aquatic pollutants. Often such samplers are used in the kinetic stage, and in situ calibration is necessary. Most commonly, exchange kinetics are derived from the release rates of performance reference compounds (PRCs). In this study, a complementary calibration approach was developed, in which measuring the contaminant mass ratio (CMR) from two samplers with different thicknesses allows the dissolved concentrations to be determined. This new CMR calibration was tested (1) in a laboratory experiment with defined and constant concentrations and (2) in the field, at a storm water retention site. Silicone passive samplers with different thicknesses were used to sample a range of dissolved polycyclic aromatic hydrocarbons. In the laboratory study, the concentrations derived from the CMR calibration were compared with those from water extraction and passive dosing and differences below a factor 2 were found. In the field study, CMR-derived concentrations were compared to those from PRC calibration. Here, differences ranged by only a factor 1 to 3 between both methods. These findings indicate that the CMR calibration can be applied as a stand-alone or complementary calibration method for kinetic passive sampling.
机译:使用单相无源采样器是用于取样生物可利用浓度的疏水性水生污染物的常用方法。通常,这种采样器用于动力学阶段,并且在原位校准是必要的。最常见的是,交换动力学源自性能参考化合物(PRCS)的释放率。在该研究中,开发了一种互补校准方法,其中测量来自具有不同厚度的两种取样器的污染物质量比(CMR)允许确定溶解的浓度。该新的CMR校准在具有定义和恒定浓度的实验室实验中进行了测试(1),在雨水保留部位处具有定义和恒定浓度和(2)。使用具有不同厚度的硅胶无源取样器对一系列溶解的多环芳烃进行样品。在实验室研究中,将源自CMR校准的浓度与来自水提取和无源剂量的浓度进行比较,发现低于因子2以下的差异。在田间研究中,将CMR衍生的浓度与来自PRC校准的研究进行比较。这里,两种方法之间的差异仅仅是一个因子1到3。这些发现表明CMR校准可以应用于单独的独立或互补校准方法,用于动力学采样。

著录项

  • 来源
    《Environmental Science & Technology》 |2020年第24期|15759-15767|共9页
  • 作者单位

    Institute for Environmental Research RWTH Aachen University 52074 Aachen Germany;

    Institute for Environmental Research RWTH Aachen University 52074 Aachen Germany State Key Laboratory of Pollution Control and Resource Reuse School of the Environment Nanjing University 210093 Nanjing PR China;

    Passive Sampling of Organic Compounds (PaSOC) 8821LV Kimswerd The Netherlands;

    Institute for Environmental Research RWTH Aachen University 52074 Aachen Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);