首页> 外文期刊>Environmental Science & Technology >Effects of Environmentally Relevant Concentration Exposure Profiles on Polar Organic Chemical Integrative Sampler (POCIS) Sampling Rates
【24h】

Effects of Environmentally Relevant Concentration Exposure Profiles on Polar Organic Chemical Integrative Sampler (POCIS) Sampling Rates

机译:环境相关浓度暴露曲线对极性有机化学综合采样器(POCIS)采样率的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Polar organic chemical integrative sampler (POCIS) is a passive sampling device that offers many advantages over traditional discrete sampling methods, but quantitative time-weighted average (TWA) concentrations rely heavily on the robustness of sampling rates. The effects of changing chemical concentration exposures on POCIS sampling rates and its ability to operate in an integrative regime were investigated for 12 pesticides across a range of environmentally relevant concentrations. In five independent 21-day experiments, POCIS devices were exposed to these compounds at constant concentrations ranging from 3 to 60 μg/L and multiple pulsed concentrations with maximum peaks ranging from 5 to 150 μg/L (TWA concentrations = 3 to 92 μg/ L). For the 21-day exposures to constant and pulsed concentrations, there were no significant differences in the POCIS sampling rates between corresponding TWA concentrations. Similarly, there was no significant effect on POCIS ability to operate in an integrative regime. However, loss of linearity was visible for some replicates when exposed to higher pulsed concentrations over an extended period. Modeling and Freundlich isotherms did not predict sorbent saturation, but the extraction and reconstitution protocol likely contributed to atrazine dissolution and subsequent underestimation of sorbed chemical mass when HLB adsorption exceeded 400 μg.
机译:Polar有机化学综合采样器(POCIS)是一种被动采样装置,提供了与传统的离散采样方法相比的许多优势,但定量的时间加权平均(TWA)浓度严重依赖于采样率的稳健性。改变化学浓度暴露对POCI采样率的影响及其在综合制度中运行的能力,以12种农药在一系列环境相关的浓度上进行了调查。在五个独立的21天实验中,POCIS装置以3至60μg/ L的恒定浓度暴露于这些化合物,以及多个脉冲浓度,最大峰值范围为5-150μg/ L(Twa浓度= 3至92μg/ l)。对于恒定和脉冲浓度的21天暴露,对应于TWA浓度之间的POCI采样率没有显着差异。同样,对PoCIS在综合制度中运营的能力没有显着影响。然而,当在较长时间内暴露于较高的脉冲浓度时,一些重复可见线性丧失。造型和Freundlich等温机没有预测吸附剂饱和,但提取和重构方案可能导致阿特拉津溶解,并且随后在HLB吸附超过400μg时低估吸附化学品质量。

著录项

  • 来源
    《Environmental Science & Technology》 |2020年第14期|8848-8856|共9页
  • 作者单位

    Department of Chemistry and Biochemistry Baylor University Waco Texas 76798 United States;

    Department of Chemistry and Biochemistry Baylor University Waco Texas 76798 United States;

    Department of Chemistry and Biochemistry Baylor University Waco Texas 76798 United States;

    Department of Statistical Science Baylor University Waco Texas 76798 United States;

    Syngenta Crop Protection LLC Greensboro North Carolina 27409 United States;

    Department of Chemistry and Biochemistry Baylor University Waco Texas 76798 United States;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号