首页> 外文期刊>Environmental Pollution >Estimations of benchmark dose for urinary metabolites of coke oven emissions among workers
【24h】

Estimations of benchmark dose for urinary metabolites of coke oven emissions among workers

机译:工人焦炉排放尿代谢物基准剂量的估算

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Coke oven emissions (COEs), usually composed of polycyclic aromatic hydrocarbons (PAHs) and so on, may alter the relative telomere length of exposed workers and have been linked with adverse health events. However, the relevant biological exposure limits of COEs exposure has not been evaluated from telomere damage. The purpose of this study is to estimate benchmark dose (BMD) of urinary PAHs metabolites from COEs exposure based on telomere damage with RTL as a biomarker. A total of 544 exposed workers and 238 controls were recruited for participation. High-performance liquid chromatography and qPCR were used to detect concentrations of urinary mono-hydroxylated PAHs and relative telomere length in peripheral blood leukocytes for all subjects. The benchmark dose approach was used to estimate benchmark dose (BMD) and its lower 95% confidence limit (BMDL) of urinary OH-PAHs of COEs exposure based on telomere damage. Our results showed that telomere length in the exposure group (0.75 (0.51, 1.08)) was shorter than that in the control group (1.05 (0.76,1.44))(P 0.05), and a dose-response relationship was shown between telomere damage and both 1-hydroxypyrene and 3hydroxyphenanthrene in urine. The BMDL of urinary 1-hydroxypyrene from the optimal model for telomere damage was 1.96, 0.40, and 1.01 (mmol/mol creatinine) for the total, males, and females group, respectively. For 3-hydroxyphenanthrene, the BMDL was 0.94, 0.33, and 0.49 (mmol/mol creatinine) for the total, males, and females. These results contribute to our understanding of telomere damage induced by COEs exposure and provide a reference for setting potential biological exposure limits. (C) 2021 Elsevier Ltd. All rights reserved.
机译:焦炉排放(COES),通常由多环芳烃(PAH)等组成,可以改变暴露工人的相对端粒长度,并与不利的健康事件相关联。然而,尚未从端粒损伤中评估COE暴露的相关生物暴露限制。本研究的目的是估算基于用RTL作为生物标志物的端粒损伤的CoES暴露的尿PAHS代谢物的基准剂量(BMD)。招募了共有544名暴露工人和238个控件参加。高效液相色谱和QPCR用于检测所有受试者外周血白细胞中尿单羟基化的PAHs和相对端粒长度的浓度。基准剂量方法用于根据端粒损伤估计基准剂量(BMD)及其尿OH-PAHS的95%置信极限(BMDL)。我们的研究结果表明,暴露组的端粒长度(0.75(0.51,1.08))短于对照组(1.05(0.76,1.44))(P <0.05),并且在端粒之间显示了剂量 - 反应关系尿液中损伤和1-羟基吡啶和3羟基苯蒽。来自端粒损伤最佳模型的尿1-羟基丙烯的BMDL分别为总,男性和雌性组的1.96,0.40和1.01(mmol / mol肌酸酐)。对于3-羟基苯蒽,BMD1为总,雄性和女性为0.94,0.33和0.49(Mmol / Mol肌酸酐)。这些结果有助于我们对COE暴露引起的端粒损伤的理解,并为设定潜在的生物暴露限制提供参考。 (c)2021 elestvier有限公司保留所有权利。

著录项

  • 来源
    《Environmental Pollution》 |2021年第3期|116434.1-116434.8|共8页
  • 作者单位

    Zhengzhou Univ Dept Occupat Hlth & Occupat Dis Coll Publ Hlth Zhengzhou 450001 Peoples R China;

    Henan Inst Occupat Hlth Dept Occupat Hlth Zhengzhou 450052 Peoples R China;

    Zhengzhou Univ Dept Occupat Hlth & Occupat Dis Coll Publ Hlth Zhengzhou 450001 Peoples R China;

    Zhengzhou Univ Dept Occupat Hlth & Occupat Dis Coll Publ Hlth Zhengzhou 450001 Peoples R China;

    Zhengzhou Univ Dept Epidemiol & Biostatist Coll Publ Hlth Zhengzhou 450001 Peoples R China;

    Harvard TH Chan Sch Publ Hlth Dept Environm Hlth Boston MA 02115 USA;

    Emory Univ Rollins Sch Publ Hlth Gangarosa Dept Environm Hlth Atlanta GA 30322 USA;

    Anyang Iron & Steel Grp Corp Dept Safety Management Off Anyang 455000 Peoples R China;

    Zhengzhou Univ Dept Occupat Hlth & Occupat Dis Coll Publ Hlth Zhengzhou 450001 Peoples R China;

    Zhengzhou Univ Dept Occupat Hlth & Occupat Dis Coll Publ Hlth Zhengzhou 450001 Peoples R China|Key Lab Nanomed & Hlth Inspect Zhengzhou Zhengzhou 450001 Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Coke oven emissions; Telomere damage; Urinary mono-hydroxylated PAHs; Benchmark dose; Biological exposure limit;

    机译:焦炉排放;端粒损伤;尿单羟基化的PAHS;基准剂量;生物暴露极限;
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号