A specific 2-year program to monitor and test both the vadose zone and the saturated zone, coupled with a numerical analysis, was performed to evaluate the overall performance of slurry wall systems for containment of contaminated areas. Despite local physical confinement (slurry walls keyed into an average 2-m-thick aquitard), for at least two decades, high concentrations of chlorinated solvents (up to 110 mg l~(-1)) have been observed in aquifers that supply drinking water close to the city of Milan (Italy). Results of monitoring and in situ tests have been used to perform an unsaturated-saturated numerical model. These results yielded the necessary quantitative information to be used both for the determination of the hydraulic properties of the different media in the area and for the calibration and validation of the numerical model. Backfill material in the shallower part of the investigated aquifer dramatically affects the natural recharge of the encapsulated area. A transient simulation from wet to drought periods highlights a change in the ratio between leakages from lateral barriers that support a specific scenario of water loss through the containment system. The combination of monitoring and modelling allows a reliable estimate of the overall performance of the physical confinement to be made without using any invasive techniques on slurry wall.
机译:进行了一个为期两年的监测和测试渗流带和饱和带的计划,并进行了数值分析,以评估用于隔离受污染区域的泥浆墙系统的整体性能。尽管局部进行了物理限制(泥浆壁的平均厚度为2米厚的阿基色浆),但至少有二十年的时间,在提供饮用水的含水层中已观察到高浓度的氯化溶剂(高达110 mg l〜(-1))。水接近米兰市(意大利)。监测和现场测试的结果已用于执行非饱和饱和数值模型。这些结果产生了必要的定量信息,可用于确定该地区不同介质的水力特性,以及用于数值模型的校准和验证。被调查含水层较浅部分的回填材料极大地影响了被封装区域的自然补给。从潮湿到干旱时期的瞬态模拟突出显示了横向障碍物泄漏之间比率的变化,这些横向障碍物支持通过安全壳系统进行水损失的特定情况。监视和建模的结合允许可靠地估计物理限制的总体性能,而无需在浆壁上使用任何侵入性技术。

著录项

  • 来源
    《Environmental Monitoring and Assessment》 |2012年第2期|p.607-624|共18页
  • 作者单位

    GHS, Dept. Geotechnical Engineering and Geosciences, Universitat Politecnica de Catalunya-BarcelonaTech, C/Jordi-Girona 1-3, 08034, Barcelona, Spain;

    Dipartimento di Scienze della Terra 'A. Desio', Universita degli Studi di Milano, via Mangiagalli 34, 20133, Milan, Italy;

    Dipartimento di Scienze della Terra 'A. Desio', Universita degli Studi di Milano, via Mangiagalli 34, 20133, Milan, Italy;

    Dipartimento di Scienze della Terra 'A. Desio', Universita degli Studi di Milano, via Mangiagalli 34, 20133, Milan, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    slurry wall; groundwater monitoring; numerical modeling; leakage; Milan (Italy);