摘要

In the present study, a separation/preconcen-tration procedure for determination of aluminum in water samples has been developed by using a new atomic absorption spectrometer concept with a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochroma-tor, and a charge-coupled device array detector. Sample solution pH, sample volume, flow rate of sample solution, volume, and concentration of eluent for solid-phase extraction of Al chelates with 4-[(dicya-nomethyl)diazenyl] benzoic acid on polymeric resin (Duolite XAD-761) have been investigated. The adsorbed aluminum on resin was eluted with 5 mL of 2 mol L~(-1) HNO_3 and its concentration was determined by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Under the optimal conditions, limit of detection obtained with HR-CS FAAS and Line Source FAAS (LS-FAAS) were 0.49 μgL~(-1) and3.91 μgL~(-1), respectively. The accuracy of the procedure was confirmed by analyzing certified materials (NIST SRM 1643e, Trace elements in water) and spiked real samples. The developed procedure was successfully applied to water samples.
机译:在本研究中,通过使用以高强度氙气短弧灯作为连续辐射源,高分辨率双倍原子吸收光谱仪的新型原子吸收光谱仪概念,开发了一种用于测定水中样品中铝的分离/预富集程序。 -echelle单色仪和一个电荷耦合器件阵列检测器。在聚合物树脂(Duolite XAD-761)上用4-[(双氰基-甲基)二氮烯基]苯甲酸固相萃取铝螯合物的样品溶液pH,样品体积,样品溶液流速,体积和洗脱液浓度被调查。用5 mL 2 mol L〜(-1)HNO_3洗脱树脂上吸附的铝,并通过高分辨率连续谱源火焰原子吸收光谱法(HR-CS FAAS)测定其浓度。在最佳条件下,HR-CS FAAS和线源FAAS(LS-FAAS)的检出限分别为0.49μgL〜(-1)和3.91μgL〜(-1)。通过分析认证的材料(NIST SRM 1643e,水中的痕量元素)和加标的真实样品,可以确认该方法的准确性。所开发的程序已成功应用于水样。

著录项

  • 来源
    《Environmental Monitoring and Assessment》 |2013年第3期|2745-2753|共9页
  • 作者

    Harun Ciftci; Cigdem Er;

  • 作者单位

    Department of Chemistry, Faculty of Science and Arts,Ahi Evran University,Kirsehir, Turkey;

    Department of Chemistry, Faculty of Science,Gazi University,Ankara, Turkey;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Preconcentration; Trace metal; Aluminum; Separation;