Active filter used as a controlled reactance to prevent harmonic resonance in interconnected offshore power systems

机译:有源滤波器用作可控电抗,以防止互连的海上电力系统中的谐波谐振

获取原文
获取原文并翻译 | 示例
           

摘要

Harmonic resonance is of particular concern in the design and operation of interconnected offshore power systems. This paper shows that it is possible to attenuate such resonance using an active filter. A new control method is proposed which can assess the system condition from a harmonic point of view and take into account the relative distribution of exciting frequencies and system resonant modes. Measured system busbar voltage is the only feedback required by the filter controller and the power system condition is initially unknown and variable. A series of time domain simulation results are presented to illustrate the effectiveness and limitations of the 'active harmonic damper' while some practical design considerations are highlighted.
机译:谐波谐振在互连海上电力系统的设计和运行中特别重要。本文表明,可以使用有源滤波器来衰减这种共振。提出了一种新的控制方法,该方法可以从谐波的角度评估系统状态,并考虑激励频率和系统谐振模式的相对分布。测得的系统母线电压是滤波器控制器所需的唯一反馈,而电源系统的状态最初是未知的且可变的。给出了一系列时域仿真结果,以说明“有源谐波阻尼器”的有效性和局限性,同时重点介绍了一些实际设计注意事项。