The cascade refrigeration system has been applied to heat pump water heaters to overcome the problems which arise from the high compression ratio at low ambient temperature. In this study, the performance of a cascade heat pump water heating system is investigated with a quasi-steady state analysis to find out the transient behavior of the system. The water-heating system consists of the cascade heat pump water heater, which uses R134a and R410A as refrigerants, and a water storage tank. The steady-state cascade heat pump model is developed based on experimental results and the dynamic storage tank model is created by thermodynamic equations. The model computes the several major parameters related with the system performance, such as the heating capacity, the power consumption, the COP (coefficient of performance), and the temperature distribution in a storage tank. Moreover, the performance of the system is calculated for various conditions to research the influence of ambient temperature and hot water demand.
机译:级联制冷系统已应用于热泵热水器,以克服由于在低环境温度下高压缩比而引起的问题。在这项研究中,通过准稳态分析来研究级联热泵热水系统的性能,以找出系统的瞬态行为。该水加热系统由使用R134a和R410A作为制冷剂的级联热泵热水器和一个储水箱组成。根据实验结果建立了稳态级联热泵模型,并通过热力学方程建立了动态​​储罐模型。该模型计算与系统性能相关的几个主要参数,例如加热能力,功耗,COP(性能系数)和储罐中的温度分布。此外,针对各种条件计算系统的性能,以研究环境温度和热水需求的影响。

著录项

  • 来源
    《Energy》 |2013年第15期|283-294|共12页
  • 作者单位

    School of Mechanical and Aerospace Engineering, Seoul National University, Gwanak-ro 1, Gwanak-gu, Seoul 151-744, Republic of Korea;

    School of Mechanical and Aerospace Engineering, Seoul National University, Gwanak-ro 1, Gwanak-gu, Seoul 151-744, Republic of Korea;

    School of Mechanical and Aerospace Engineering, Seoul National University, Gwanak-ro 1, Gwanak-gu, Seoul 151-744, Republic of Korea;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Cascade refrigeration system; Heat pump water heater; Numerical simulation; Quasi-steady state; System performance;

    机译:级联制冷系统;热泵热水器;数值模拟准稳态;系统性能;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号