首页> 外文期刊>Energy >Experimental investigation of energy and exergy performance of secondary loop automotive air-conditioning systems using low-GWP (global warming potential) refrigerants
【24h】

Experimental investigation of energy and exergy performance of secondary loop automotive air-conditioning systems using low-GWP (global warming potential) refrigerants

机译:使用低全球升温潜能值(全球升温潜能值)制冷剂的二次回路汽车空调系统能量和火用性能的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, the energy and exergy performance of secondary loop systems (2LPs) using HFC-152a and HC-290 was investigated. These 2LPs were compared with a HFC-134a direct expansion system as a baseline system. As compared with the baseline, tested refrigerant charge amount was reduced by 28% for the HFC-152a 2LP and 60% for the HC-290 2LP. Under typical 35 ℃ ambient temperature condition, the coefficient of performance (COP) of the HFC-152a 2LP was increased by 5% for highway driving conditions and 10% for idling conditions. Regarding the HC-290 2LP, the COP was increased by 8% under highway driving conditions and was decreased by 15% under idling conditions. As for the exergy performance, the total exergy destruction was reduced by roughly 9.6% for the HFC-152a 2LP and 14.3% for the HC-290 2LP as compared with HFC-134a baseline during highway driving conditions. A theoretical potential of HC-290 2LP idling performance is that its idling COP would be approximately 15% higher and its exergy destruction would be 12.5% lower than those of the HFC-134a baseline.
机译:在这项研究中,研究了使用HFC-152a和HC-290的次级回路系统(2LP)的能量和火用性能。将这些2LP与作为基准系统的HFC-134a直接扩展系统进行了比较。与基准相比,HFC-152a 2LP的测试制冷剂充注量减少了28%,HC-290 2LP的测试制冷剂充注量减少了60%。在典型的35℃环境温度条件下,HFC-152a 2LP的性能系数(COP)在高速公路行驶条件下增加了5%,在空转条件下增加了10%。对于HC-290 2LP,在高速公路行驶条件下,COP升高了8%,在空转条件下,COP降低了15%。至于火用性能,与HFC-134a基准相比,HFC-152a 2LP的总火用破坏减少了9.6%,HC-290 2LP的总火用破坏减少了14.3%。 HC-290 2LP空转性能的理论潜力在于,其空转COP大约比HFC-134a基准高15%,其火用破坏度降低12.5%。

著录项

  • 来源
    《Energy》 |2014年第4期|819-831|共13页
  • 作者单位

    Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, 3157 Glenn Martin Hall Bldg., College Park, MD 20742, USA;

    Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, 3157 Glenn Martin Hall Bldg., College Park, MD 20742, USA;

    Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, 3157 Glenn Martin Hall Bldg., College Park, MD 20742, USA;

    Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, 3157 Glenn Martin Hall Bldg., College Park, MD 20742, USA;

    Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, 3157 Glenn Martin Hall Bldg., College Park, MD 20742, USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Secondary loop; HFC-152a; HC-290; Exergy destruction; Mobile air conditioning;