首页> 外文期刊>Energy >Replacing critical radiators to increase the potential to use low-temperature district heating - A case study of 4 Danish single-family houses from the 1930s
【24h】

Replacing critical radiators to increase the potential to use low-temperature district heating - A case study of 4 Danish single-family houses from the 1930s

机译:更换重要的散热器以增加使用低温集中供热的潜力-以1930年代4栋丹麦单户住宅为例

获取原文
获取原文并翻译 | 示例
           

摘要

Low-temperature district heating is a promising technology for providing homes with energy-efficient heating in the future. However, it is of great importance to maintain thermal comfort in existing buildings when district heating temperatures are lowered. This case study evaluated the actual radiator sizes and heating demands in 4 existing Danish single-family houses from the 1930s. A year-long dynamic simulation was performed for each of the houses to evaluate the potential to lower the heating system temperatures. The results indicate that there is a large potential to use low-temperature district heating in existing single-family houses. In order to obtain the full potential of low-temperature district heating, critical radiators must be replaced. Based on a novel method, a total of nine radiators were identified to be critical to ensure thermal comfort and low return temperatures in two of the case houses. If these radiators were replaced it would be possible to lower the average heating system temperatures to 50 degrees C/27 degrees C in all four houses. (C) 2016 Elsevier Ltd. All rights reserved.
机译:低温区域供热是一种有前途的技术,可为将来的家庭提供节能供暖。但是,当降低区域供暖温度时,保持现有建筑物的热舒适性非常重要。该案例研究评估了1930年代以来丹麦现有的4套单户住宅的实际散热器尺寸和供暖需求。对每个房屋进行了为期一年的动态模拟,以评估降低供暖系统温度的潜力。结果表明,在现有的单户住宅中使用低温集中供热的潜力很大。为了充分发挥低温区域供暖的潜力,必须更换关键的散热器。基于一种新颖的方法,确定了总共九个散热器对于确保两个案例房屋的热舒适性和低返回温度至关重要。如果更换了这些散热器,则可以将所有四个房屋的平均加热系统温度降低到50摄氏度/ 27摄氏度。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号