首页> 外文期刊>Energy >Performance analysis of a solar-assisted combined cooling, heating and power system with an improved operation strategy
【24h】

Performance analysis of a solar-assisted combined cooling, heating and power system with an improved operation strategy

机译:具有改进操作策略的太阳能辅助组合冷却,加热和电力系统性能分析

获取原文
获取原文并翻译 | 示例
           

摘要

Performance and economics of a solar-assisted combined cooling, heating and power (SCCHP) system mainly depend on the system & rsquo;s structure, operation strategy and choice of facility capacity. The SCCHP analyzed in this paper, contains a solid oxide fuel cell (SOFC) that is the power generation unit, a heat recovery system, a photovoltaic (PV) system, solar evacuated tube collectors (ETC), an absorption chiller, an electric chiller and a heat storage tank. An improved operation strategy, termed as best operation condition point (BOCP) strategy, is proposed and applied in this SCCHP system. With the proposed operation strategy, the capacities of the main equipment are optimized based on a particle swarm optimization (PSO) algorithm. In addition, a case study of an apartment building in Guangzhou is conducted to verify the feasibility of the proposed SCCHP system structure and optimal operation strategy. Compared with these separating supply system, the optimized CCHP system has an excellent performance in energy saving. It can save 15141.63 KWh electric energy and increase heat output by 170183.57 MJ per year. Accordingly, the return on investment is 2.55 and the payback period is 11.2 years.(c) 2021 Elsevier Ltd. All rights reserved.
机译:太阳能辅助组合冷却,加热和电力(SCCHP)系统的性能和经济学主要取决于系统和rsquo; S结构,运行策略和设施容量的选择。本文分析的SCCHP含有固体氧化物燃料电池(SOFC),即发电单元,热回收系统,光伏(PV)系统,太阳疏散​​管收集器(ETC),吸收冷却器,电动冷却器和储料箱。提出了一种改进的操作策略,称为最佳操作条件点(BOCP)策略,并应用于该SCCHP系统。利用所提出的操作策略,主要设备的容量基于粒子群优化(PSO)算法进行了优化。此外,还进行了对广州公寓楼的案例研究,以验证所提出的SCCHP系统结构和最优运行策略的可行性。与这些分离供应系统相比,优化的CCHP系统具有出色的节能性能。它可以节省15141.63千瓦时电能,并每年增加170183.57 MJ。因此,投资回报率为2.55,投资回收期为11.2岁。(c)2021 elestvier有限公司保留所有权利。

著录项

  • 来源
    《Energy》 |2021年第15期|120516.1-120516.15|共15页
  • 作者单位

    North China Elect Power Univ State Key Lab Alternate Elect Power Syst Renewabl Beijing Peoples R China;

    Guoneng Nanjing Elect Power Test & Res Co Ltd Nanjing 210046 Peoples R China;

    North China Elect Power Univ State Key Lab Alternate Elect Power Syst Renewabl Beijing Peoples R China;

    Guangzhou Power Supply Bur Guangdong Power Grid C Guangzhou 510600 Peoples R China;

    Univ Adelaide Sch Mech Engn Adelaide SA 5005 Australia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    SCCHP; Solar energy; Operation strategy; Evaluation criterion;

    机译:SCCHP;太阳能;操作策略;评估标准;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号