首页> 外文期刊>Energy >Experimental study on the performance of single-piston free-piston expander-linear generator
【24h】

Experimental study on the performance of single-piston free-piston expander-linear generator

机译:单活塞自由活塞式扩展器 - 线性发生器性能的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, a single-piston free-piston expander-linear generator test system for the power-electricity conversion is presented using compressed air as the working fluid. This study investigated the effect of intake time and intake pressure on the performance of the test system. Examples include the following: in-cylinder pressure, bias displacement, one-way time, indicated work, output electric energy, and work electricity conversion efficiency in a single cycle using the position-time control method with the intake position of 21and 45 mm. Result shows that: in the operational process of the test system, all values obtained when the piston runs from top dead center to bottom dead center are all different compared with those obtained when the piston runs from bottom dead center to top dead center. When the test system operates with low intake pressure and short intake time, the working chamber without a piston rod will over-expand. With the increase of intake time or intake pressure, the bias displacement, indicated work, and one-way output electric energy show an increasing trend. Moreover, the one-way time shows a decreasing trend and eventually tends to a fixed value, and the one-way work-electricity conversion efficiency initially increases and then decreases.(c) 2021 Elsevier Ltd. All rights reserved.
机译:在该研究中,使用压缩空气作为工作流体来提出用于电力转换的单活塞自由活塞式扩展器 - 线性发生器测试系统。本研究研究了进气时间和进气压力对测试系统性能的影响。实例包括以下:缸内压力,偏置位移,单向时间,指示的工作,输出电能,以及使用位置时间控制方法的单循环中的工作电力转换效率,使用25mm的进气位。结果表明:在测试系统的操作过程中,与当活塞从底死中心延伸到顶部死亡中心时,当活塞从顶部死点运行时获得的所有值都不同。当测试系统以低进气压力和短摄取时间运行时,没有活塞杆的工作室将过度膨胀。随着进气时间或进气压力的增加,偏置位移,指示的工作和单向输出电能显示出增加的趋势。此外,单向时间显示趋势的降低,最终趋于固定值,单向工作 - 电转换效率最初增加,然后减少。(c)2021 elestvier有限公司保留所有权利。

著录项

  • 来源
    《Energy》 |2021年第15期|119724.1-119724.11|共11页
  • 作者单位

    Beijing Univ Technol Fac Environm & Life Key Lab Enhanced Heat Transfer & Energy Conservat Beijing Key Lab Heat Transfer & Energy Convers MO Beijing 100124 Peoples R China;

    Beijing Univ Technol Fac Environm & Life Key Lab Enhanced Heat Transfer & Energy Conservat Beijing Key Lab Heat Transfer & Energy Convers MO Beijing 100124 Peoples R China;

    Beijing Univ Technol Fac Environm & Life Key Lab Enhanced Heat Transfer & Energy Conservat Beijing Key Lab Heat Transfer & Energy Convers MO Beijing 100124 Peoples R China;

    Shandong Univ Technol Sch Transportat & Vehicle Engn Zibo 255000 Peoples R China;

    Beijing Univ Technol Fac Environm & Life Key Lab Enhanced Heat Transfer & Energy Conservat Beijing Key Lab Heat Transfer & Energy Convers MO Beijing 100124 Peoples R China;

    Beijing Univ Technol Fac Environm & Life Key Lab Enhanced Heat Transfer & Energy Conservat Beijing Key Lab Heat Transfer & Energy Convers MO Beijing 100124 Peoples R China;

    Univ Wisconsin Richard J Resch Sch Engn Mech Engn Green Bay WI 54311 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Bias displacement; One-way time; Indicated work; Output electric energy; Work-electricity conversion efficiency; Single-piston free-piston expander-linear generator;

    机译:偏置位移;单向时间;表明工作;输出电能;工作 - 电力转换效率;单活塞自由活塞式扩展器 - 线性发电机;