The effect of electronic module's shape on friction factors and heat transfer coefficients in rectangular channels with two opposite walls, included module's was determined in electronic circuit boards by keeping pressure drop constant in a given range. Generally for electronic modules, square shape is used. But in this study, different shape of modules which is cylindrical was investigated. Two different heights of cylindrical parameters, 3 mm and 1.5 mm, were used in order to find the effect of the height on heat transfer. Experiments were realized for channel height 6, 8 and 10 mm, for both modules height. The investigation was performed with both laminar and turbulent forced flow for Reynolds number from 250 to 7000. The wall temperature was held constant at 85 ℃. The global measurement technique was used to determine the temperature difference and pressure drop in the test duct. The result revealed that the heat transfer performance of module height 3 mm is much better than the module height 1.5 mm.
机译:电子模块的形状对具有两个相对壁的矩形通道(包括模块)中的摩擦系数和传热系数的影响是通过将压降保持在给定范围内在电子电路板上确定的。通常对于电子模块,使用正方形。但是在这项研究中,研究了不同形状的圆柱形模块。为了找到高度对传热的影响,使用了两个不同高度的圆柱参数3 mm和1.5 mm。对两个模块高度的通道高度分别为6、8和10 mm进行了实验。用层流和湍流强迫流动进行研究,雷诺数从250到7000。壁温保持恒定在85℃。整体测量技术用于确定测试管道中的温差和压降。结果表明,模块高度为3 mm的传热性能远远优于模块高度为1.5 mm的传热性能。