首页> 外文期刊>Energy Conversion & Management >Heat pipe for cooling of electronic equipment
【24h】

Heat pipe for cooling of electronic equipment

机译:电子设备冷却用热管

获取原文
获取原文并翻译 | 示例
           

摘要

This article experimentally investigates the thermal performance of the heat pipe cooling system with the thermal resistance model. Evaporator and condenser, which are the two main devices, connect to each other to form a closed system. The liquid water absorbs heat from heat source and evaporates in the evaporator. The evaporating fluid moves toward the condenser, and then condenses in the condenser. The experimental parameters are different evaporation surfaces, fill ratios of working fluid and input heating powers. The result shows that the evaporation resistance and the condensation resistance both grow with increasing heating power and decreasing fill ratio. Flooding is found at the fill ratio of 20% with the evaporation surface noted Etched Surface 2 when heating power is above 120 W. Flooding phenomenon is caused by the opposite flow direction of vapor and liquid in a closed two-phase system. According to the result, the lowest total thermal resistance is 0.65 ℃/W by the evaporation surface noted Etched Surface 2 at 30% fill ratio.
机译:本文通过热阻模型对热管冷却系统的热性能进行了实验研究。蒸发器和冷凝器是两个主要设备,它们相互连接以形成一个封闭的系统。液态水从热源吸收热量并在蒸发器中蒸发。蒸发的流体向冷凝器移动,然后在冷凝器中冷凝。实验参数是不同的蒸发表面,工作流体的填充率和输入的加热功率。结果表明,随着加热功率的增加和填充率的降低,耐蒸发性和耐凝结性均增加。当加热功率超过120 W时,以20%的填充率出现水淹,且蒸发表面标记为蚀刻表面2。在封闭的两相系统中,由于蒸气和液体的相反流动方向而导致水淹现象。根据结果​​,以刻蚀表面2表示的蒸发表面在填充率为30%时,最低总热阻为0.65℃/ W。