首页> 外文期刊>IEEE Transactions on Energy Conversion >Practical on-line partial discharge tests for turbine generators and motors
【24h】

Practical on-line partial discharge tests for turbine generators and motors

机译:涡轮发电机和电动机的实用在线局部放电测试

获取原文
获取原文并翻译 | 示例
           

摘要

Several utilities have found partial discharge testing to be very useful for identifying motors or generators with deteriorated stator winding insulation. Such partial discharge tests are sensitive to problems associated with overheated insulation, loose stator bars, and pollution, all of which can cause in-service failures with long associated outages and high repair/rewind costs. Unfortunately, the partial discharge test is not widely applied since present test methods require considerable skill to perform, and/or require machine outages. These problems are due to the stator winding partial discharges being masked by high levels of internal and external electrical noise. The authors describe how partial discharge tests have now been developed which eliminate the effect of noise, thus allowing plant personnel to perform the test without any machine outage.
机译:一些公用事业公司发现局部放电测试对于识别定子绕组绝缘性能下降的电动机或发电机非常有用。这种局部放电测试对与绝缘过热,定子条松动和污染有关的问题敏感,所有这些问题都可能导致服务故障,并伴随长期停机和高昂的维修/倒带成本。不幸的是,局部放电测试没有得到广泛应用,因为当前的测试方法需要相当高的技能来执行和/或需要机器停机。这些问题是由于定子绕组的局部放电被高水平的内部和外部电气噪声所掩盖。作者描述了现在如何开发消除噪声影响的局部放电测试,从而使工厂人员可以在不中断任何机器的情况下进行测试。