This article presents measuring results of the thermal performance of duo-pitched tiled woodframe roof designs. The roofs have been monitored in a test building, exposed to the outside climate. The experiment was part of a programme to study the hygrothermal performance of highly insulated envelope parts in situ, in order to investigate whether a good thermal quality (U = 0.2 W/(m~2 K)) is achievable with current residential construction practices in Belgium. The results show the effect of wind on the thermal performance of duo-pitched roofs. The measured thermal properties of the roof components are compared to the design values, and related to the wind speeds and directions registered near the test building. The established thermal effects are explained using tracer gas tests to show the pattern of wind driven air flow in the roofs.
机译:本文介绍了双间距平铺木结构屋顶设计的热性能测量结果。在暴露于外界气候的测试大楼中对屋顶进行了监控。该实验是研究原位高绝缘围护结构部件吸湿热性能的程序的一部分,目的是调查在目前的居住建筑实践中是否可以达到良好的热质量(U = 0.2 W /(m〜2 K))。比利时。结果表明,风对双斜屋顶热性能的影响。将测得的屋顶组件的热性能与设计值进行比较,并与测试建筑物附近记录的风速和风向相关。通过使用示踪气体测试来解释已建立的热效应,以显示屋顶中风驱动气流的模式。