This paper expands Ghaddar et al. [N. Ghaddar, K. Ghali, R. Saadeh, A. Keblawi, Design charts for combined chilled ceiling displacement ventilation system (1438-RP), ASHRAE Transactions, 143 (2) (2008) 574-587] design charts of combined chilled ceiling (CC) displacement ventilation (DV) system to operating sensible load ranges from 40 W/m~2 to 100 W/m~2. It develops a global correlation of system load and operational parameters, with comfort measured by vertical temperature gradient and indoor air quality measured by the stratification height. The correlations are used for a known transient load profile in generating optimal settings of the CC/DV system operational parameters and associated energy consumption.rnAn example is illustrated to show how the correlation could be used to size the system and to provide optimized control of the CC/DV system operation at low computational cost. Results of the current model are compared to the published case study of an optimized operation based on transient simulations of the space thermal model to achieve minimum operation cost [M. Mossolly, N. Ghaddar, K. Ghali, L. Jensen, Optimized operation of combined chilled ceiling displacement ventilation system using genetic algorithm, ASHRAE Transactions, 143 (2) (2008) 541-554]. The design correlations resulted in good agreement with published data (within 3% error in energy consumption and average 6% error in predictions of comfort and stratification height) at 1/4 of the computational time. The presented methodology provides an alternative for using the correlation for supervisory online controllers for the CC/DV system based on physically derived correlations.
机译:本文扩展了Ghaddar等。 [N. Ghaddar,K. Ghali,R. Saadeh,A. Keblawi,组合式冷冻天花板置换通风系统的设计图(1438-RP),ASHRAE Transactions,143(2)(2008)574-587]组合式冷冻天花板的设计图( CC)排量通风(DV)系统可在40 W / m〜2到100 W / m〜2的工作负载范围内工作。它建立了系统负载和运行参数的全局关联,其中舒适度通过垂直温度梯度衡量,而室内空气质量通过分层高度衡量。相关关系用于生成CC / DV系统操作参数和相关能耗的最佳设置的已知瞬态负载曲线。举例说明了一个示例,说明如何使用相关关系来调整系统大小并提供对系统的优化控制。 CC / DV系统以较低的计算成本运行。将当前模型的结果与已发表的基于空间热模型的瞬态仿真的优化运行案例研究进行比较,以实现最低运行成本[M. Mossolly,N. Ghaddar,K. Ghali,L. Jensen,“使用遗传算法优化组合式冷吊顶通风系统的运行”,ASHRAE Transactions,143(2)(2008)541-554]。设计相关性与公布的数据(在能耗的3%内的误差和舒适度和分层高度的预测中的平均6%的误差)之间的计算时间相差1/4。所提出的方法为基于物理派生的相关性将相关性用于CC / DV系统的监控在线控制器提供了一种替代方法。

著录项

  • 来源
    《Energy and Buildings》 |2009年第11期|1155-1164|共10页
  • 作者单位

    Department of Mechanical Engineering, Faculty of Engineering and Architecture, American University of Beirut, P.O. Box 11-236, Riad El Solh, Beirut 1107 2020, Lebanon;

    Department of Mechanical Engineering, Faculty of Engineering and Architecture, American University of Beirut, P.O. Box 11-236, Riad El Solh, Beirut 1107 2020, Lebanon;

    Department of Mechanical Engineering, Faculty of Engineering and Architecture, American University of Beirut, P.O. Box 11-236, Riad El Solh, Beirut 1107 2020, Lebanon;

    Department of Building Services Engineering, Lund University, Lund, Sweden;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    design charts for chilled ceiling; displacement ventilation; optimized control of cooling systems;

    机译:冷藏天花板的设计图;置换通风冷却系统的优化控制;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号