Shading is a technique used to reduce the cooling demand in buildings and save energy. This paper investigates the possibility of reducing the electrical demand and saving energy by shading the condensers of air-conditioning (A/C) equipment. A limiting analysis compares the performance of several A/C systems with ideal shade to those with ideal solar heat gain. The comparison is based on a theoretical model and data from equipment catalogs. The results show that the theoretical increase in the coefficient of performance (COP) due to shading is within 2.5%. Furthermore, this small improvement in ideal efficiency decreases at higher ambient temperatures, when enhancements to efficiency are more needed. A sensitivity analysis shows that the small COP enhancement is not significantly affected by assumed variables. The actual efficiency improvement due to shading is not expected to exceed 1%, and the daily energy savings will be lower. The findings indicate that condenser shading alone, without evapo-transpiration, is not an effective measure to improve efficiency or save energy.
机译:遮阳是一种用于减少建筑物的制冷需求并节省能源的技术。本文研究了通过遮蔽空调(A / C)设备的冷凝器来减少电力需求并节省能源的可能性。极限分析将几种具有理想阴影的空调系统的性能与具有理想太阳热增益的空调系统的性能进行了比较。比较是基于理论模型和设备目录中的数据进行的。结果表明,由于遮挡而导致的性能系数(COP)的理论增加在2.5%以内。此外,当更需要提高效率时,理想效率的这种小提高会在较高的环境温度下降低。敏感性分析表明,较小的COP增强不受假定变量的显着影响。阴影带来的实际效率提高预计不会超过1%,并且每天的节能量将更低。研究结果表明,没有蒸发蒸腾作用的冷凝器遮光罩并不是提高效率或节省能源的有效措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号