With the current movement towards net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.
机译:随着当前向净零能耗建筑发展,许多技术都以其卓越的能源效率为重点而得到推广。可变制冷剂流量(VRF)和地源热泵(GSHP)系统可能是其中最具竞争力的技术。但是,很少有研究报告与GSHP系统相比VRF系统的能效。在本文中,对空气源VRF和GSHP系统之间的能效进行了初步比较。计算机仿真结果表明,GSHP系统比空气源VRF系统在两种选定的美国气候下对小型办公楼进行空调调节时更加节能。通常,GSHP系统比空气源VRV系统具有更高的能源效率,尤其是在建筑物中有很大的热负荷时。对于具有较少热负荷的建筑物,GSHP系统在能源效率方面仍可以比空气源VRF系统更好,但是所节省的能源可能是微不足道的。

著录项

  • 来源
    《Energy and Buildings》 |2010年第5期|p.584-589|共6页
  • 作者

    Xiaobing Liu; Tianzhen Hong;

  • 作者单位

    Climatemaster. 7300 S.W. 44th Street, Oklahoma City, OK 73179, United States;

    Lawrence Berkeley National Laboratory, EETD, 1 Cyclotron Road, Berkeley, CA 94720, United States;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    building simulation; DOE-2; energy efficiency; GSHP; VRF;

    机译:建筑模拟;DOE-2;能源效率;地源热泵VRF;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号