首页> 外文期刊>Energy and Buildings >Performance evaluation of a hybrid photovoltaic thermal double pass facade for space heating
【24h】

Performance evaluation of a hybrid photovoltaic thermal double pass facade for space heating

机译:用于空间供暖的混合光伏热双通道立面的性能评估

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents the performance evaluation of a hybrid photovoltaic thermal (Semi transparent PVT) double pass facade for space heating. The thermal model has been developed by using the energy balance equations of the proposed hybrid photovoltaic thermal double pass facade under quasi-steady state con dition. Numerical computations have been carried out for the composite climate of New Delhi, India. An analysis has been carried out to calculate annual energy and exergy gain for the hybrid photovoltaic ther mal double pass facade. On the basis of numerical results it has been observed that the annual thermal and electrical energy are 480.81 kWh and 469.87 kWh respectively. The yearly overall thermal energy gener ated by the system has been calculated as 1729.84 kWh. It is also observed that the room air temperature increases by 5-6℃ than the ambient air temperature for a typical winter day.
机译:本文介绍了用于空间供暖的混合光伏热(半透明PVT)双程立面的性能评估。通过在拟稳态条件下,使用拟议的混合光伏热双程立面的能量平衡方程,开发了热模型。已经对印度新德里的复合气候进行了数值计算。已经进行了分析以计算混合光伏热双层通道立面的年能量和火用增益。根据数值结果,可以发现年热能和电能分别为480.81 kWh和469.87 kWh。该系统每年产生的总热能经计算为1729.84千瓦时。还可以观察到,在典型的冬季,室内空气温度比环境空气温度升高5-6℃。