首页> 外文期刊>Energy and Buildings >Performance evaluation under the actual operating condition of a vertical ground source heat pump system in a school building
【24h】

Performance evaluation under the actual operating condition of a vertical ground source heat pump system in a school building

机译:某校舍垂直地面源热泵系统实际运行条件下的性能评估

获取原文
获取原文并翻译 | 示例
       

摘要

This study is to evaluate the performance of a ground source heat pump (GSHP) system installed in the Pusan National University, Korea. The GSHP system consists of ground heat exchanger (GHE), measuring devices and heat pumps which have 2 compressors (inverter type and fixed type). The closed vertical type GHE is constructed with 24 boreholes of 175 m in depth. The outdoor temperature, the indoor temperature and relative humidity, the inlet and outlet temperature of circulating water are obtained. Also, the electricity consumption of compressor and cooling (heating) load are measured in order to analyze the COP of heat pump. From the measuring data, the variation of ground temperature at 2.5 m, 5.0 m in depth are affected by outdoor air temperature. But it is proved that the ground temperature is almost constant below 10 m in depth. In cooling period, the COP of the heat pump is 6.0-10.9 at partial load condition, while the overall system COP is 4.3-7.4. In heating period, the COP of the heat pump is 4.3-8.3 at partial load condition, while the overall system COP is 3.0-6.2.
机译:本研究旨在评估韩国釜山国立大学安装的地源热泵(GSHP)系统的性能。 GSHP系统由地面热交换器(GHE),测量设备和热泵组成,它们具有2台压缩机(变频式和固定式)。封闭式立式GHE具有24个深度为175 m的钻孔。得到室外温度,室内温度和相对湿度,循环水的进出水温度。另外,为了分析热泵的COP,测量压缩机的电力消耗和冷却(加热)负荷。根据测量数据,室外空气温度会影响2.5 m,5.0 m深度处的地面温度变化。但是事实证明,地面温度在10 m以下时几乎是恒定的。在冷却期间,热泵的COP在部分负载条件下为6.0-10.9,而整个系统的COP为4.3-7.4。在供暖期间,在部分负载条件下,热泵的COP为4.3-8.3,而整个系统的COP为3.0-6.2。

著录项

  • 来源
    《Energy and Buildings》 |2012年第7期|p.1-6|共6页
  • 作者单位

    School of Mechanical Engineering, Pusan National University, San 30, Jangjeon-Dong, Kumjung-Ku, Busan 609-735, Republic of Korea;

    School of Mechanical Engineering, Pusan National University, San 30, Jangjeon-Dong, Kumjung-Ku, Busan 609-735, Republic of Korea;

    School of Mechanical Engineering, Pusan National University, San 30, Jangjeon-Dong, Kumjung-Ku, Busan 609-735, Republic of Korea;

    School of Mechanical Engineering, Pusan National University, San 30, Jangjeon-Dong, Kumjung-Ku, Busan 609-735, Republic of Korea;

    LG Electronics, 391-2 Gaeumjeong-dong, Changwon City, Cyeongnam, Republic of Korea;

    LG Electronics, 391-2 Gaeumjeong-dong, Changwon City, Cyeongnam, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ground source heat pump; cooling performance; eating performance; cround heat exchanger;

    机译:地源热泵;冷却性能饮食表现;圆形热交换器;
  • 入库时间 2022-08-18 00:10:01