摘要

In this study, we present an experimental analysis of a direct expansion (DX) geothermal heat pump (GHP) installed in the Thermal Technology Center (TTC) of the Ecole de technologie superieure in Montreal. The residential heating system studied consists of three geothermal 30m deep wells, which use R22 as refrigerant. During the test campaign, which ran over a one-month period in early spring, the coefficient of performance of the heat pump varied between 2.70 and 3.44, with a daily average of 2.87. The heating capacity reached a daily average of 8.04 kW, for a cooling water constant volumetric flow rate of 0.38 Ls~(-1). The mean the ground heat extraction rate from was 58.2 W m~(-1). The tests performed helped to highlight a pressure drop coupled with a relatively large superheating revealing a flow rate mal-distribution in geothermal evaporators. The effects of some factors (condenser cooling water inlet temperature, condensing temperature, pressure drop in the evaporator, thermal properties of soil and grout) that affect DX system performance are also presented. Finally, a comparative study between the use of electricity and the DX heat pump as home heating source shows that the DX heat pump provides savings of approximately 70% over the electricity.
机译:在这项研究中,我们对安装在蒙特利尔高等技术学院热技术中心(TTC)中的直接膨胀(DX)地热热泵(GHP)进行了实验分析。研究的住宅供暖系统由三个深30m的地热井组成,这些井使用R22作为制冷剂。在初春进行了一个月的测试活动期间,热泵的性能系数在2.70和3.44之间变化,每天的平均值为2.87。当冷却水的恒定体积流量为0.38 Ls〜(-1)时,热容量达到每日平均8.04 kW。的平均地热提取率为58.2 W m〜(-1)。进行的测试有助于突出压降和相对较大的过热现象,从而揭示地热蒸发器中的流量分配不均。还介绍了影响DX系统性能的一些因素(冷凝器冷却水入口温度,冷凝温度,蒸发器中的压降,土壤和水泥浆的热特性)的影响。最后,在电力使用和DX热泵作为家庭供暖源之间的比较研究表明,DX热泵比电力节省了大约70%。

著录项

  • 来源
    《Energy and Buildings》 |2014年第6期|290-300|共11页
  • 作者单位

    Thermal Technology Center (TTC), Department of Mechanical Engineering, Ecole de technologic superieure, Universite du Quebec, 1100, Notre-Dame Street West, Montreal H3C 1K3, Canada,Mechanical Engineering Department, Ecole de technologie superieure, 1125 William Street, Montreal H3C 1P7, Canada;

    Thermal Technology Center (TTC), Department of Mechanical Engineering, Ecole de technologic superieure, Universite du Quebec, 1100, Notre-Dame Street West, Montreal H3C 1K3, Canada;

    Thermal Technology Center (TTC), Department of Mechanical Engineering, Ecole de technologic superieure, Universite du Quebec, 1100, Notre-Dame Street West, Montreal H3C 1K3, Canada;

    Thermal Technology Center (TTC), Department of Mechanical Engineering, Ecole de technologic superieure, Universite du Quebec, 1100, Notre-Dame Street West, Montreal H3C 1K3, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Geothermal; Heat pump; Direct expansion (DX); Heating capacity; Heat extraction rate; Coefficient of performance; Electricity;

    机译:地热;热泵;直接扩展(DX);加热能力;排热率;性能系数;电力;