This paper aims to determine the optimal design and operating conditions of an air-to-air thermoelectric heat pump (THP) composed of thermoelectric modules (TEMs) and two heat sinks, coupled to an energy-efficient building. We focus on the optimal number of TEMs and the optimal electrical current for three standard cases. The performance is quantified using two different coefficients of performance (COP) definitions: performance of THP only (COP_(HP)) and performance of THP coupled to an energy-efficient building (COP_u). These COP are also studied for both instantaneous and seasonal conditions. We show that for each coupling, a range of modules exists, with which the maximum performance of the THP can be approached, by simply adapting the electrical current for each condition. Finally, the seasonal performance COP_(HP)~s/COP_u~s for the French city of Macon is estimated and compared for the three cases considered. The original sizing approach proposed here leads to a slight increase of the COP_(HP)~s/COP_u~s (up to +4%), compared to the classical design based on instantaneous nominal conditions (norm). Moreover, we show that the optimal number of modules can be largely reduced (up to -39% for the cases considered) compare with nominal condition method.
机译:本文旨在确定由热电模块(TEM)和两个散热器组成的空对空热电热泵(THP)的最佳设计和运行条件,并与一栋节能建筑相连。我们关注三种标准情况下的TEM最佳数量和最佳电流。使用两种不同的性能系数(COP)定义量化性能:仅THP的性能(COP_(HP))和与节能建筑耦合的THP的性能(COP_u)。还针对瞬时和季节性条件研究了这些COP。我们表明,对于每种耦合,都存在一系列模块,通过简单地为每种情况调整电流,就可以达到THP的最大性能。最后,估计并比较了法国梅肯市的季节性表现COP_(HP)〜s / COP_u〜s,并考虑了三种情况。与基于瞬时标称条件(标准)的经典设计相比,此处提出的原始尺寸确定方法导致COP_(HP)〜s / COP_u〜s略有增加(最高+ 4%)。此外,我们表明,与标称条件方法相比,可以最大程度地减少模块的最佳数量(对于所考虑的情况,最多可以减少-39%)。

著录项

  • 来源
    《Energy and Buildings》 |2014年第2期|106-116|共11页
  • 作者单位

    LOCIE-CNRS UMR 5271, Universite de Savoie, Polytech'Annecy-Chambery, Savoie Technolac, 73376 Le Bourget-du-Lac, France;

    LOCIE-CNRS UMR 5271, Universite de Savoie, Polytech'Annecy-Chambery, Savoie Technolac, 73376 Le Bourget-du-Lac, France;

    LOCIE-CNRS UMR 5271, Universite de Savoie, Polytech'Annecy-Chambery, Savoie Technolac, 73376 Le Bourget-du-Lac, France;

    EDF - R&D ECLEER (European Centre and Laboratories for Energy Efficiency Research), France;

    EDF - R&D MMC (Departement Materiaux et Mecanique des Composants), France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Thermoelectric heat pump; Optimal design; Energy-efficiency building; Exhaust/supply mechanical ventilation; system;

    机译:热电热泵;优化设计;节能建筑;排气/供应机械通风;系统;