Heat output and uniformity of surface temperature distribution are primarily concerned by designers and users of radiant floor heating. The testing approach, testing conditions and calculation of the heat output at each stage of program are different among the test standards. In this paper, a mathematical model to calculate surface temperature and heat output of radiant floor heating system was proposed. Measured data from experiments was used to validate the proposed model. Based on this simulation model, four current test standards in China, Europe, America and Japan were simulated. The simulation results show that the heat output of the same sample is different under the four test standards. Meanwhile, simulations were carried out at various non-heating surface temperatures. The results indicate that the non-heating surface temperature has a significant impact on the heat output of the radiant floor. The differences in the simulations of heating capacity vary from 2% to 7%. Hence, a parameter, the temperature difference between average water temperature of test sample and area weighted average temperature of non heating surfaces, is introduced to revise the heat output characteristic equation based on the Chinese test standard. (C) 2017 Elsevier B.V. All rights reserved.
机译:辐射地板采暖的设计者和用户主要关心热量输出和表面温度分布的均匀性。在测试标准中,程序的每个阶段的测试方法,测试条件和热量输出的计算均不同。提出了一种计算地板辐射采暖系统表面温度和热量输出的数学模型。来自实验的测量数据用于验证所提出的模型。基于该仿真模型,对中国,欧洲,美国和日本的四个当前测试标准进行了仿真。仿真结果表明,在四种测试标准下,同一样品的热量输出是不同的。同时,在各种非加热表面温度下进行了模拟。结果表明,非加热表面温度对辐射地板的热输出有显着影响。热容量模拟的差异从2%到7%不等。因此,引入了一个参数,即测试样品的平均水温与非加热表面的面积加权平均温度之间的温差,以根据中国的测试标准修正热输出特性方程。 (C)2017 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Energy and Buildings》 |2017年第11期|198-206|共9页
  • 作者单位

    Tianjin Univ, Sch Environm Sci & Engn, Haihe Educ Area, Tianjin 300350, Peoples R China|Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Weijin Rd 92, Tianjin 300072, Peoples R China;

    Tianjin Univ, Sch Environm Sci & Engn, Haihe Educ Area, Tianjin 300350, Peoples R China;

    Tianjin Univ, Sch Environm Sci & Engn, Haihe Educ Area, Tianjin 300350, Peoples R China;

    Tianjin Univ, Sch Environm Sci & Engn, Haihe Educ Area, Tianjin 300350, Peoples R China;

    Tianjin Univ, Sch Environm Sci & Engn, Haihe Educ Area, Tianjin 300350, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Radiant floor heating; Thermal performance; Test standard; Non-heating surface;