首页> 外文期刊>Energy and Buildings >Experimental and analytical approach on the Trombe wall thermal performance parameters characterization
【24h】

Experimental and analytical approach on the Trombe wall thermal performance parameters characterization

机译:Trombe墙体热性能参数表征的实验和分析方法

获取原文
获取原文并翻译 | 示例
           

摘要

An analytical and experimental analysis on the Trombe wall thermal performance was carried out for different conditions of ventilation openings and occlusion device operation. Experimental results allowed to determine temperature fluctuation, heat flux, heat delay and air velocity at the ventilation openings. A calculation methodology was applied to estimate the heat gains and losses through the system using experimental data. Ventilation openings and occlusion device effect was immediately visible in the temperature fluctuation and, consequentelly, in the heat gains and losses. Experimental.results showed that, when there was no occlusion device, massive wall external surface temperature values exceeded 60 degrees C and, when it was placed, reduced to 30 degrees C or less. Heat took almost 3 times more to achieve the interior of the test cell when the ventilation openings were closed. Air velocity increased following a diagonally pattern from the bottom to the top of the ventilation opening and its values varied between 0.10 m/s and 0.40 m/s, leading to air flow values between 0.002 m(3)/s and 0.008 m(3)/s. The calculation methodology application allowed to determine the total gains through the system for a continuous period. The impact of the system operation on the different thermal performance parameters was observed. (C) 2017 Elsevier B.V. All rights reserved.
机译:对通气孔和闭塞装置操作的不同条件下的Trombe壁热性能进行了分析和实验分析。实验结果可以确定通风口处的温度波动,热通量,热延迟和空气速度。应用了一种计算方法,以使用实验数据估算通过系统的热量得失。通风口和闭塞装置的效果在温度波动中立即可见,因此在热量得失中也可见。实验结果表明,当没有闭塞装置时,大的壁外表面温度值超过60摄氏度,放置时降低到30摄氏度或更低。当通风孔关闭时,热量花费了将近3倍才能达到测试电池的内部。风速从通风孔的底部到顶部以对角线的形式增加,其值在0.10 m / s和0.40 m / s之间变化,从而导致气流值在0.002 m(3)/ s和0.008 m(3)之间)/ s。计算方法应用程序允许确定连续一段时间通过系统的总收益。观察到系统运行对不同热性能参数的影响。 (C)2017 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Energy and Buildings》 |2017年第9期|262-280|共19页
  • 作者单位

    Univ Beira Interior, C MADE Ctr Mat & Bldg Technol, P-6201001 Covilha, Portugal|Univ Tras Os Montes & Alto Douro UTAD, ECT Sch Sci & Technol, P-5000801 Quinta De Prados, Vila Real, Portugal;

    Univ Tras Os Montes & Alto Douro UTAD, ECT Sch Sci & Technol, P-5000801 Quinta De Prados, Vila Real, Portugal|Univ Tras Os Montes & Alto Douro, INESC TEC INESC Technol & Sci, INESC Porto, Quinta De Prados, Vila Real, Portugal|Univ Tras Os Montes & Alto Douro, ECT Sch Sci & Technol, Quinta De Prados, Vila Real, Portugal;

    Univ Beira Interior, C MADE Ctr Mat & Bldg Technol, P-6201001 Covilha, Portugal|Univ Beira Interior, P-6201001 Covilha, Portugal;

    Univ Beira Interior, C MADE Ctr Mat & Bldg Technol, P-6201001 Covilha, Portugal|Univ Tras Os Montes & Alto Douro UTAD, ECT Sch Sci & Technol, P-5000801 Quinta De Prados, Vila Real, Portugal;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Trombe wall; Thermal performance; Experimental work; Analytical methodology; Ventilation openings; Occlusion device;

    机译:锥壁;热性能;实验工作;分析方法;通风孔;闭塞装置;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文