首页> 外文期刊>Energy and Buildings >Heat-flow variability of suspended timber ground floors: Implications for in-situ heat-flux measuring
【24h】

Heat-flow variability of suspended timber ground floors: Implications for in-situ heat-flux measuring

机译:悬浮木地板的热流变异性:原位热通量测量的意义

获取原文
获取原文并翻译 | 示例
           

摘要

Reducing space heating energy demand supports the UK's legislated carbon emission reduction targets and requires the effective characterisation of the UK's existing housing stock to facilitate retrofitting decision-making. Approximately 6.6 million UK dwellings pre-date 1919 and are predominantly of suspended timber ground floor construction, the thermal performance of which has not been extensively investigated. This paper examines suspended timber ground floor heat-flow by presenting high resolution in-situ heat-flux measurements undertaken in a case study house at 15 point locations on the floor. The results highlight significant variability in observed heat-flow: point U-values range from 0.56 +/- 0.05 to 1.18 +/- 0.11 Win(-2) K-1. This highlights that observing only a few measurements is unlikely to be representative of the whole floor heat-flow and the extrapolation from such point values to whole floor U-value estimates could lead to its over- or under-estimation. Floor U-value models appear to underestimate the actual measured floor U-value in this case study. This paper highlights the care with which in-situ heat flux measuring must be undertaken to enable comparison with models, literature and between studies and the findings support the unique, high-resolution in-situ monitoring methodology used in this study for further research in this area. (C) 2016 Elsevier B.V. All rights reserved.
机译:减少空间供暖的能源需求支持英国立法的碳减排目标,并要求对英国现有住房存量进行有效表征,以促进决策的改进。在1919年之前,约有660万英国住宅,且主要为悬浮木地板建筑,其热性能尚未得到广泛研究。本文通过介绍在案例研究室中地板上15个点位置进行的高分辨率原位热通量测量,研究了悬浮木地板的热流。结果突出显示了观察到的热流的显着可变性:点U值的范围从0.56 +/- 0.05到1.18 +/- 0.11 Win(-2)K-1。这突出表明,仅观察少量测量值不可能代表整个地板的热流,并且从这样的点值到整个地板的U值估计值的推断可能会导致其高估或低估。在此案例研究中,地板U值模型似乎低估了实际测得的地板U值。本文重点介绍了必须进行现场热通量测量以确保与模型,文献和研究之间进行比较的注意事项,研究结果支持了本研究中使用的独特的高分辨率现场监测方法,以便在本研究中进行进一步的研究。区域。 (C)2016 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Energy and Buildings》 |2017年第3期|396-405|共10页
  • 作者单位

    Univ Sheffield, Sheffield Sch Architecture, Western Bank, Sheffield S10 2TN, S Yorkshire, England;

    Univ Salford, Sch Built Environm, G16a,Cockcroft Bldg, Salford M5 4WT, Lancs, England;

    UCL, Energy Inst, 14 Upper Woburn Pl, London WC1H 0NN, England;

    Univ Salford, Sch Built Environm, G16a,Cockcroft Bldg, Salford M5 4WT, Lancs, England;

    UCL, Inst Environm Design & Engn, 14 Upper Woburn Pl, London WC1H 0NN, England;

    UCL, Inst Environm Design & Engn, 14 Upper Woburn Pl, London WC1H 0NN, England;

    Univ Helsinki, POB 65, FIN-00014 Helsinki, Finland;

    UCL, Energy Inst, 14 Upper Woburn Pl, London WC1H 0NN, England;

    UCL, Energy Inst, 14 Upper Woburn Pl, London WC1H 0NN, England;

    UCL, Energy Inst, 14 Upper Woburn Pl, London WC1H 0NN, England;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    building performance; In-situ U-values; Pre-1919 housing; Retrofit; Suspended timber ground floors; Thermal performance;

    机译:建筑性能;原位U值;1919年前的住房;翻新;悬浮木地板;热性能;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号