首页> 外文期刊>Energy and Buildings >Field study of heating performance of three ground-source heat pumps in Canadian single-family houses
【24h】

Field study of heating performance of three ground-source heat pumps in Canadian single-family houses

机译:加拿大单家庭房屋三个地源热泵采暖性能的现场研究

获取原文
获取原文并翻译 | 示例
       

摘要

This paper is the second part of a two-part study on the performance of ground-source heat pumps (GSHPs) in single-family detached houses in Canada. In Part I the cooling performance of two GSHPs was tested, analyzed and evaluated over one cooling season. In this paper, the heating performance of three vertical closed-loop water-to-air GSHP systems installed in three new single-family detached houses in Innisfil (80 km north of Toronto, Canada) is monitored, analyzed and evaluated over one heating season. Results show that GSHP A, GSHP B and GSHP C were able to meet the peak heating load without using the auxiliary heating element. The seasonal coefficient of performance of heat pump of GSHP A, GSHP B and GSHP C is 4.2, 4.0 and 3.4, respectively, whereas the seasonal coefficient of performance of the GSHP system of GSHP A, GSHP B and GSHP C is 3.8, 3.4 and 2.7, respectively. GSHP A has the highest COP mainly because it is equipped with a variable speed compressor while GSHP B and GSHP C are equipped with two-stage compressors. The average temperature of water leaving the ground loop of GSHP A, GSHP B and GSHP C is 3.9 degrees C, 3.1 degrees C and 2.7 degrees C, respectively, where the average temperature of water leaving the ground loop varied by up to 6.3 degrees C throughout the heating season. The total power consumption and operating cost of GSHP A, GSHP B and GSHP C are less than conventional air-source heat pumps by up to 46%, 40% and 24%, respectively. It is concluded that GSHPs operate at high COPs without operational problems even in very cold climates if designed, sized and installed correctly. (c) 2021 Elsevier B.V. All rights reserved.
机译:本文是对加拿大单独拆卸房屋的地面源热泵(GSHPS)性能的两部分研究的第二部分。在第二部分中,测试,分析和评估了两种GSHP的冷却性能。在本文中,在Innisfil的三个新的单人家庭分离房屋中安装了三个垂直闭环水流GSHP系统的加热性能(加拿大多伦多北部80公里处),分析和评估了一个加热季节。结果表明,GSHP A,GSHP B和GSHP C能够在不使用辅助加热元件的情况下满足峰值加热负载。 GSHP A,GSHP B和GSHP C的热泵的季节性分别分别为4.2,4.0和3.4,而GSHP A,GSHP B和GSHP C的GSHP系统的季节性系数分别为3.8,3.4和2.7分别。 GSHP A具有最高的警察主要是因为它配备了一个变速压缩机,而GSHP B和GSHP C配有两级压缩机。离开GSHP A,GSHP B和GSHP C的地面环的平均温度分别为3.9摄氏度,3.1摄氏度和2.7摄氏度,其中水的平均温度留下了最多6.3摄氏度整个加热季节。 GSHP A,GSHP B和GSHP C的总功耗和运营成本分别小于传统的空气源热泵,分别高达46%,40%和24%。结论是,GSHP在高COPS在没有操作问题的情况下运行,即使在非常寒冷的气候中,如果设计,大小正确,也正确安装。 (c)2021 elestvier b.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号