首页> 外文期刊>Energy and Buildings >Control strategies for switchable roof insulation systems applied to US residential homes
【24h】

Control strategies for switchable roof insulation systems applied to US residential homes

机译:适用于美国住宅的可切换屋顶绝缘系统的控制策略

获取原文
获取原文并翻译 | 示例
           

摘要

This paper summarizes the main findings for evaluating the effectiveness of simplified and advanced control strategies to operate switchable insulation systems applied to the attic of US residential buildings. Specifically, the evaluation analysis is performed for five US representative climates to determine the performance of several control options for dynamic insulation systems to minimize the heating and cooling energy end-uses for US homes. The control strategies considered include scheduled settings, temperature-based rule sets, and optimal control schemes. The comparative analysis results clearly indicate that the switchable insulation systems even when only applied to attics have significant potentials in reducing the cooling energy use of US residential homes especially those located in mild climates. Even when operated with simplified controls such as time-scheduled controls and temperature-based rule-sets, dynamic insulations are capable of providing substantial energy savings. In particular, controls using rules based on mean air and sol-air temperatures result in cooling energy savings ranging from 8% to 43% for all US climates. When optimal controls are used to operate attic dynamic insulation systems, up to 40% additional savings in cooling energy can be achieved compared to the best simplified controls at least when the building is located in Golden, CO. (C) 2020 Elsevier B.V. All rights reserved.
机译:本文总结了评估简化和先进控制策略的有效性,以操作适用于美国住宅建筑物阁楼的可转换绝缘系统的有效性。具体地,对五个美国代表性气候进行评估分析,以确定用于动态绝缘系统的多个控制选项的性能,以最大限度地减少美国房屋的加热和冷却能源最终用途。考虑的控制策略包括预定的设置,基于温度的规则集和最佳控制方案。比较分析结果清楚地表明可切换绝缘系统即使仅应用于仪器时也具有显着的潜力,降低了美国住宅的冷却能源使用,尤其是位于温和气候中的居民。即使在用简化的控制中操作,例如时间调度的控制和基于温度的规则集,即动也能够提供大量的节能。特别是,使用基于平均空气和溶胶 - 空气温度的规则的控制导致所有美国气候的降温节能从8%到43%。当最佳控制用于操作阁楼动态绝缘系统时,与至少当建筑物位于Golden,Co的最佳简化控制相比,可以实现冷却能量的高达40%的冷却能量节省。(c)2020 Elsevier BV所有权利预订的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号