In small commutation motors, arc discharges are generated between the brushes (carbon) and commutators (copper) in opposing positions, accompanied by electromagnetic noise. An arc discharge is produced both between the brush and commutator (Cu cathode) and between the commutator and brush (C cathode), and these two phenomena with different polarities cannot be separately observed from outside. In this investigation the arc discharges of different current polarities and their associated noise characteristics are analyzed. Experiments are performed with different opposing electrodes, consisting of C and Cu. The opening voltage is 40 V DC. The current in the closed state is 2 A. The load is an inductance of 0.85 mH. The arc voltage and noise when the electrical contacts are opened in both the Cu cathode and C cathode cases are analyzed as time series. It is found that the maximum noise level in each operation is about 20 dB higher for the Cu cathode case than for the C cathode case. The time of maximum noise generation in each operation is close to the time of arc extinction for the Cu cathode case but is in the middle of the arc discharge for the C cathode case. The time derivative of the voltage waveform near arc extinction and the amplitude of the noise waveform before detection are larger in the Cu cathode case than in the C cathode case.
机译:在小型换向电动机中,在相反位置的电刷(碳)和换向器(铜)之间会产生电弧放电,并伴有电磁噪声。在电刷和换向器(Cu阴极)之间以及换向器和电刷(C阴极)之间都会产生电弧放电,这两种极性不同的现象无法从外部单独观察到。在这项研究中,分析了不同电流极性的电弧放电及其相关的噪声特性。使用由C和C​​u组成的不同对电极进行实验。开启电压为40 V DC。闭合状态下的电流为2A。负载的电感为0.85 mH。将Cu阴极和C阴极情况下的电触点断开时的电弧电压和噪声按时间序列进行分析。可以发现,在每次操作中,最大的噪声水平对于铜阴极外壳要比碳阴极外壳高约20 dB。每次操作中产生最大噪声的时间与Cu阴极外壳的灭弧时间相近,但在C阴极外壳的消弧时间中。与C阴极相比,灭弧时的电压波形的时间导数和检测前的噪声波形的振幅大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号