Time-domain reflectometry (TDR), the most widely used testing method for fault-detection in cables, is tested against soft faults of increasing severity. The intensity of TDR echoes is proven to be an unreliable estimator of fault severity, since both the bandwidth of testing signals and the length of the fault have a strong impact on the results. Moreover, it is proven that faults of very different severity may generate virtually identical echoes making it impossible to assess how critical a fault is. Simple frequency-domain estimators are introduced, based on models of a fault reflectivity, leading to minimum requirements for the test bandwidth in order to accurately identify soft faults. As a practical consequence, it is concluded that only faults above a critical length can be accurately identified, implying that no clear decision can be taken about shorter faults.
机译:时域反射仪(TDR)是用于电缆故障检测的最广泛使用的测试方法,可针对严重性不断提高的软故障进行测试。 TDR回波的强度被证明不能可靠地估计故障的严重程度,因为测试信号的带宽和故障的长度都会对结果产生重大影响。此外,事实证明,严重程度不同的故障可能会产生几乎相同的回波,从而无法评估故障的严重程度。基于故障反射率模型,引入了简单的频域估计器,从而导致对测试带宽的最低要求,以便准确识别软故障。实际的结论是,只能准确地识别出临界长度以上的故障,这意味着无法就较短的故障做出明确的决定。