A simple method is introduced by which, during measurements of noise figure and gain, the output reflection coefficient of the device under test can be adjusted to some constant value without the use of a network analyser, thereby keeping the noise figure of the noise measurement system constant. This removes an important source of error in noise figure and noise parameter measurements. A circulator and tuning network (e.g. a three-stub tuner) are used, but there is no need for the circulator to be tuned for perfect circulation. In an experimental test to verify the accuracy of the method, excess noise temperatures and available gains of a two-port were measured for a wide range of values of the complex reflection coefficient of the noise source and compared against values calculated from the measured scattering parameters of the same two-port.
机译:介绍了一种简单的方法,在测量噪声系数和增益时,无需使用网络分析仪就可以将被测设备的输出反射系数调整为某个恒定值,从而保持噪声测量系统的噪声系数。不变。这消除了噪声系数和噪声参数测量中的重要误差源。使用了循环器和调谐网络(例如,三端调谐器),但是无需为使循环器完美地进行调节而对循环器进行调谐。在验证该方法准确性的实验测试中,针对噪声源的复数反射系数的宽范围值,测量了多余的噪声温度和两个端口的可用增益,并将其与根据测量的散射参数计算出的值进行了比较相同的两个端口。