On-load tap changers (OLTC) that are in critical condition and require maintenance can be selected on the basis of diagnostic measurement results. Resistance measurements are particularly suitable for assessment of OLTC degradation and to reveal OLTC defects that could lead to failure (see Figure 1). This article discusses dynamic resistance measurements (DRM) on OLTCs. In Part 1 of this series [1], DRM as a diagnostic method for OLTCs was discussed, and a few case studies were presented. In this part the interpretation of the results will be discussed.
机译:可以根据诊断测量结果选择处于紧急状态且需要维护的有载分接开关(OLTC)。电阻测量特别适合评估OLTC退化并揭示可能导致故障的OLTC缺陷(见图1)。本文讨论了OLTC上的动态电阻测量(DRM)。在本系列的第1部分[1]中,讨论了DRM作为OLTC诊断方法,并提供了一些案例研究。在这一部分中,将讨论结果的解释。