A case study on a high-voltage motor has clearly established that the major reason fo magnetic noise is the slot combination. Change in the number of rotor slot with the same cross section had given rise to the noise level reduction of 10.5 -12 dB(A). No attempt was made to reduce the air- borne noise,rnThis paper has described salient features of noise generation and controlling the same in a rotatingrnelectrical machine. The fact that the design of electric machine has to evolve the methodology to look for noise-worthiness, in addition to electromagnetic and thermal aspects.
机译:高压电动机的案例研究清楚地表明,电磁噪声的主要原因是插槽组合。具有相同横截面的转子槽数的变化已使噪声级降低了10.5 -12 dB(A)。没有尝试减少空气传播的噪声。本文描述了旋转电机中噪声产生的显着特征及其控制方法。电机的设计除了电磁和热方面,还必须发展方法论以寻求噪声价值。

著录项

  • 来源
    《Electrical India》 |2010年第7期|P.30-323436384042|共8页
  • 作者

    H V K Shetty;

  • 作者单位

    Rotating Electrical Machines Division, Jyoti Ltd. Baroda;