The push-pull mutator invertor is a d.c. arrangement with grid-controlled mercury-arc mutators operating alternately and causing an alternating current to flow in the load circuit. In the case of resistance load practically any shape of alternating voltage wave-form between rectangular form and triangular form can be produced. The shape of the alternating voltage waveform depends upon the capacitance of the invertor capacitor, a relatively small capacitance giving the alternating voltage a rectangular form and a large value making it triangular. The ripple factor of the direct current is governed by the smoothing effect of the inductance in the d.c. circuit, a small inductance causing the direct current to flow intermittently. The degree of regulation of alternating voltage at any change of load is determined by the capacitance of the invertor capacitor. A large capacitance may produce such a large voltage regulation that the curve of power output plotted against load describes a V form, the power output being increased when the load is reduced. The invertor stops working when overloaded. Calculations are carried out for approximate circuit conditions. The results of experiment agree satisfactorily with the theory.
机译:推挽变换器反相器是一个直流电。电网控制的汞弧变极器交替运行的一种布置,使交流电在负载电路中流动。在电阻负载的情况下,实际上可以产生矩形和三角形之间的任何形状的交流电压波形。交流电压波形的形状取决于逆变器电容器的电容,相对较小的电容使交流电压呈矩形,而较大的值使其变为三角形。直流电的纹波因数由直流中电感的平滑作用决定。电路中,较小的电感会导致直流电流间歇性流动。负载变化时交流电压的调节程度取决于逆变器电容器的电容。大电容可能会产生如此大的电压调节率,以至于相对于负载绘制的功率输出曲线描述为V形,当负载减小时功率输出会增加。过载时逆变器停止工作。针对近似电路条件进行计算。实验结果与理论相符。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号