首页> 外文期刊>Electrical Engineers, Journal of the Institution of >Sheath and armour losses in single-core cables for single-phase and three-phase transmission
【24h】

Sheath and armour losses in single-core cables for single-phase and three-phase transmission

机译:单相和三相传输的单芯电缆的护套损耗和铠装损耗

获取原文
获取原文并翻译 | 示例
           

摘要

The accurate practical determination of inductive losses in an a.c. system of single-core lead-covered cables is considered in detail, and test-results which are correlated with calculations are quoted by way of illustration. Bridge methods have been developed for the measurement of both the total and individual losses in single-phase and 3-phase single-core systems. These methods are shown to be capable of great accuracy. The feasibility of armouring single-core cables has been discussed by various authorities, whose opinions are widely divergent. A series of tests has been carried out, the main results of which are given herein. These show clearly the practical limitations imposed by the inductive effects from armouring each cable separately with wire armour. They also provide a sound empirical basis from which the losses in any given system may be estimated.
机译:交流中电感损耗的精确实际确定详细介绍了单芯铅包电缆系统,并通过举例说明了与计算相关的测试结果。已经开发出用于测量单相和三相单芯系统中的总损耗和单个损耗的电桥方法。这些方法显示出很高的准确性。铠装单芯电缆的可行性已由各个机构讨论,其意见分歧很大。已经进行了一系列测试,其主要结果在此给出。这些清楚地表明了由用铠装线分别铠装每根电缆的感应效应所施加的实际限制。它们还提供了可靠的经验基础,可以据此估算任何给定系统中的损失。