首页> 外文期刊>Electric power systems research >A standard method for specifying the response of hydroelectric plant in frequency-control mode
【24h】

A standard method for specifying the response of hydroelectric plant in frequency-control mode

机译:在频率控制模式下指定水力发电厂响应的标准方法

获取原文
获取原文并翻译 | 示例
           

摘要

The paper proposes a specification for the transient and steady-state responses of a hydroelectric power station operating in frequency-control mode. It can be used during design, testing and commissioning as well as forming the basis for contractual agreement on performance during normal operation. The specification gives a generic definition of how the electrical power should respond to step, ramp and random changes in frequency. The rationale for the proposed specification is discussed. A prototype transfer function is proposed as an aid to formulating a step response specification. The length of record required during random testing is discussed. The use of the specification is illustrated by considering the response of the Dinorwig pumped-storage hydroelectric station.
机译:本文提出了在频率控制模式下运行的水力发电站的瞬态和稳态响应的规范。它可以在设计,测试和调试期间使用,也可以为正常运行期间的性能合同约定奠定基础。该规范给出了电源应如何响应阶跃,斜坡和频率随机变化的一般定义。讨论了提出的规范的原理。提出了原型传递函数,以帮助制定阶跃响应规范。讨论了随机测试期间所需的记录长度。通过考虑Dinorwig抽水蓄能水电站的响应来说明该规范的使用。