首页> 外文期刊>Electric power systems research >New accurate fault location algorithm for parallel transmission lines using local measurements
【24h】

New accurate fault location algorithm for parallel transmission lines using local measurements

机译:使用局部测量的并行传输线新的精确故障定位算法

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

This paper presents a new accurate fault location algorithm for parallel transmission lines based on the distributed parameter line model. The new method requires only voltages and currents from one end of parallel lines. Based on sequence networks and boundary conditions, equations can be derived to obtain the fault location. The new method fully considers shunt capacitance of the line, and mutual impedance and mutual admittance between the lines by using accurate model for both positive- and zero- sequence circuits, and obviates the need of iterative process to compensate for the capacitance. The method is independent of fault resistance, remote infeed and source impedances. EMTP simulation studies have been conducted to generate fault cases under various fault conditions to validate the proposed method. The results have shown that the developed algorithm can achieve highly accurate fault location estimates.
机译:提出了一种基于分布参数线模型的并行输电线路精确故障定位算法。新方法仅需要来自并行线路一端的电压和电流。基于序列网络和边界条件,可以导出方程式以获得故障位置。该新方法通过对正序和零序电路使用精确模型,充分考虑了线路的并联电容以及线路之间的互阻抗和互导,并且无需进行迭代过程来补偿电容。该方法与故障电阻,远程馈电和源阻抗无关。进行了EMTP仿真研究,以在各种故障条件下生成故障案例,以验证所提出的方法。结果表明,所开发的算法可以实现高精度的故障位置估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号