Wind turbines are very vulnerable to lightning strikes due to their height, sharp edges and remote locations often with high soil resistivity. In this paper we present numerical simulations of the impedance of a typical wind turbine grounding geometry. We analyze the influence of interconnecting grounding systems of different wind turbines. IEC TR61400-24 suggests interconnection of grounding electrodes of wind turbines through horizontal electrodes (in the form of insulated or bare conductors) to achieve low steady-state grounding resistance. The analysis takes into account the frequency dependence of the soil electrical parameters. We show that the low frequency grounding impedance can be reduced by a factor of two or more as a result of interconnecting grounding systems. However, the reduction is significantly lower at higher frequencies because of the interconnection wire's inductance. We analyze the spatial distribution of the ground potential rise and step voltage in response to typical first and subsequent lightning return stroke current waveforms. It is shown that both, ground potential rise and step voltage can be significant along the wire, especially for high resistivity soil, and placing sensitive equipment near the interconnecting wire should be either avoided, or insulated wire should be used.
机译:由于它们的高度,锋利的边缘和远程位置通常具有高土壤电阻率,风力涡轮机非常容易受到雷击。在本文中,我们呈现了典型风力涡轮机接地几何的阻抗的数值模拟。我们分析了不同风力涡轮机互连接地系统的影响。 IEC TR61400-24建议通过水平电极(以绝缘或裸导体的形式)互连风力涡轮机接地电极以实现低稳态接地电阻。分析考虑了土壤电气参数的频率依赖性。我们表明,由于互连接地系统,低频接地阻抗可以减少两个或更多个因子。然而,由于互连线的电感,在较高频率下减小显着降低。我们响应于典型的第一和随后的雷电行程电流波形来分析地电位上升和阶跃电压的空间分布。结果表明,沿着电线可以显着,尤其是对于高电阻率土,并且应避免互连线附近放置敏感设备,或者应使用绝缘电线。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号