首页> 外文期刊>Electric Power Applications, IET >No-load losses based method to detect demagnetisation fault in permanent magnet synchronous motors with parallel branches
【24h】

No-load losses based method to detect demagnetisation fault in permanent magnet synchronous motors with parallel branches

机译:基于空载损耗的并联支路永磁同步电动机退磁故障检测方法

获取原文
获取原文并翻译 | 示例
           

摘要

For permanent magnet synchronous motors with parallel branches, circulating currents are induced by a partial demagnetisation fault. The induced currents increase the losses of the motor. Therefore, detecting such a fault becomes possible by analysing the motor losses. This study analyses the effects of the partial demagnetisation fault and defines an index, which is the ratio of increased losses and total losses when the motor is under no-load conditions, to monitor the condition of the rotor magnets. The method is easily implemented and sensitive to the fault. The experimental results validate the effectiveness of the proposed method.
机译:对于带有并联支路的永磁同步电动机,循环电流是由部分退磁故障引起的。感应电流会增加电动机的损耗。因此,通过分析电动机损耗,能够检测出这样的故障。这项研究分析了部分退磁故障的影响并定义了一个指标,该指标是电动机在空载条件下增加的损耗与总损耗的比值,以监控转子磁体的状态。该方法易于实施并且对故障敏感。实验结果验证了该方法的有效性。