首页> 外文期刊>Ecotoxicology and Environmental Safety >Determination of As, Cr, Mo, Sb, Se and V in agricultural soil samples by inductively coupled plasma optical emission spectrometry after simple and rapid solvent extraction using choline chloride-oxalic acid deep eutectic solvent
【24h】

Determination of As, Cr, Mo, Sb, Se and V in agricultural soil samples by inductively coupled plasma optical emission spectrometry after simple and rapid solvent extraction using choline chloride-oxalic acid deep eutectic solvent

机译:氯化胆碱-草酸深共熔溶剂简单快速萃取后,通过电感耦合等离子体发射光谱法测定农业土壤样品中的砷,铬,钼,锑,硒和钒

获取原文
获取原文并翻译 | 示例
       

摘要

A rapid, simple and green ultrasound-assisted extraction method using deep eutectic solvents (DES) for extraction of As, Cr, Mo, Sb, Se and V in soil samples, has been developed. Choline chloride oxalic acid based DES was used as a solvent. The target analytes were subsequently quantified using inductively coupled plasma optical emission spectrometer (ICP OES). The parameters that affect the extraction of the target analytes was optimized using standard reference material of San Joaquin soil (SRM 2709a). In the optimization step, a two level full factorial experimental design was used. The factors under investigation include extraction time, sample mass and acid concentration. Under optimized conditions, limits of detection (LOD) and limits of quantification (LOQ) ranged from 0.009 to 0.1 and 0.03-0.314 mu g g(-1), respectively. The repeatability (n=20) estimated in terms of relative standard deviation (%RSD) ranged from 0.9% to 3.7%. The accuracy of the proposed method was carried out using SRM 2709a. The obtained and certified/indicative values were statistically in good agreement at 95% confidence level. The proposed method applied for quantification of As, Cr, Mo, Sb, Se and V in real soil samples. For comparison, the analytes of interest were also determined using a conventional acid digestion method. According to the paired t-test, the analytical results were not significant differences at 95% confidence level. The method was found to be accurate, precise and environmentally friendly.
机译:已经开发出一种快速,简单,绿色的超声辅助提取方法,该方法使用深共熔溶剂(DES)提取土壤样品中的As,Cr,Mo,Sb,Se和V。基于胆碱氯化物草酸的DES用作溶剂。随后使用电感耦合等离子体发射光谱仪(ICP OES)对目标分析物进行定量。使用San Joaquin土壤的标准参考材料(SRM 2709a)对影响目标分析物提取的参数进行了优化。在优化步骤中,使用了两级全因子实验设计。调查的因素包括提取时间,样品质量和酸浓度。在优化条件下,检出限(LOD)和定量限(LOQ)分别在0.009至0.1和0.03-0.314μg g(-1)之间。根据相对标准偏差(%RSD)估算的重复性(n = 20)在0.9%至3.7%的范围内。所提出方法的准确性是使用SRM 2709a进行的。在95%的置信水平下,获得的值和认证/指示值在统计学上吻合良好。该方法可用于实际土壤样品中As,Cr,Mo,Sb,Se和V的定量分析。为了进行比较,还使用常规酸消解法测定了目标分析物。根据配对t检验,在95%置信水平下分析结果无显着差异。发现该方法是准确,精确和环境友好的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号