Recent research efforts at Texas Tech University on impulse antenna phased array has needed to develop a reliable high voltage, high repetition rate switch that will operate with ultra low jitter. An ideal jitter of a small fraction of the risetime is required to accurately synchronize the array to steer and preserve the risetime of the radiated pulse. In [1], we showed the initial test system with sub-ns results for operations in different gases and gas mixtures. This paper discusses in detail 50 kV, 100 Hz switch operations with different gases. The effects of gases and gas mixtures have on switch performance which includes recovery rate and in particular jitter will be investigated. Gases tested include, dry air, H2, N2, and SF6, as well as H2-N2, and N2-SF6 gas mixtures. Switch jitter as a result of triggering conditions is discussed, also including a comprehensive evaluation of jitter as a function of formative delay in the various gases. The temperature of gas and its effects on switch jitter is also documented in this paper. A 50 :9;, 1 nF pulse forming line is charged to 50 kV and provides the low inductance voltage source to test the different gases. Triggering is provided by a solid state opening switch voltage source that supplies ~150 kV, 10 ns risetime pulses at a rep rate up to 100 Hz in burst mode. A hermetically sealed spark gap with a Kel-F - PCTFE (PolyChloroTriFluoroEthylene) lining is used to house the switch and high pressure gas.
机译:德州理工大学在脉冲天线相控阵上的最新研究工作需要开发一种可靠的高压,高重复频率开关,该开关将以超低抖动工作。要使阵列准确同步以控制和保持辐射脉冲的上升时间,就需要上升时间的一小部分的理想抖动。在[1]中,我们展示了具有不同测试结果的初始测试系统,可在不同的气体和混合气体中运行。本文详细讨论了使用不同气体的50 kV,100 Hz开关操作。气体和气体混合物对开关性能的影响,包括回收率,特别是抖动。测试的气体包括干燥空气,H2,N2和SF6以及H2-N2和N2-SF6的气体混合物。讨论了由触发条件引起的开关抖动,还包括对各种气体中形成延迟的函数进行的抖动综合评估。本文还记录了气体温度及其对开关抖动的影响。 50:9; 1 nF脉冲形成线被充电至50 kV,并提供低电感电压源以测试不同的气体。固态断开开关电压源提供触发功能,该模式在突发模式下以高达100 Hz的重复频率提供〜150 kV,10 ns的上升时间脉冲。带有Kel-F-PCTFE(聚氯三氟乙烯)衬里的密封火花隙用于容纳开关和高压气体。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号